Equator MD3720CEE service manual Dry Timer 50728 Replacement Procedure, Cold Test

Page 18

7)Dry Timer (50728) Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back)

Pull out the soap dispenser, plastic washer knob and dryer knob. Remove the control panel. (3 Screws)

Unfix the two screws that hold the dry timer and take out the timer. Pull out all the wires on the dry timer and replace the same.

Fix all the parts back by following the reverse procedure.

Wiring: Dry Timer

TAB

b

 

TAB1 b1

TAA1 a1

TAA

a

 

Testing Procedure:

TAC

Cold Test:

1)Turn the dryer knob to 30 and check for continuity between terminals a & a1, b & b1.

2)Check the resistance between TAC and a terminals, it should not be more than 2300 ohm.

ePlease Note: The side with b & b1 should be on the top.

18

Image 18
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Machine vibrating or vibrating noise Water leaking from doorUnit wont fill Unit is noisy Unit fills, won’t agitate / tumbleUnit won’t drain out water Unit VibratesWater fill in tub with unit off Timer doesn’t advanceWater leaks from detergent drawer Unit overfillsNo tumble action Unit keeps filling only when the unit is switched onClothes wet at the end of wash cycle Clothes cold and damp at the end of dry cycleClothes hot and damp at the end of dry cycle Long Drying TimeReplacement Procedure, Wiring & Testing of Parts Power Switch 52799 Replacement ProcedureDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Cold water valve 10820 Replacement Procedure Hot TestHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Dry Timer 50728 Replacement Procedure Cold TestHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Fusible Link / Wire with fuse 00807 Replacement Procedure Wiring Fusible LinkThermostat 00808 Replacement Procedure FEXFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk