Inlet Hoses

The inlet hoses must be fitted with the special rubber washers. These rubber washers ensure a water tight seal between the hoses and the water inlet valves to prevent water leaks. Water should flow freely into the machine, be sure that the inlet hoses are not bent or kinked.

Please read the following steps carefully (Fig.1, Fig.2)

1.Connect the gray end of the hot-water hose to the hot-water faucet (Fig.1).

2.Connect the gray end of the cold-water hose to the cold-water faucet (Fig.1).

3.Connect two pressure-reducing valves [2] to each inlet valve [1] (see Fig.2).

4.Connect the white L-shapedend of hot-water hose to the pressure-reducing valve connected to the inlet valve marked “H” (Fig.2).

5.Connect the white L-shapedend of cold-water hose to the pressure-reducing valve connected to the inlet valve marked “C” (Fig.2).

Fig 1

Fig 2

Drain Hose

Connect the drain hose to a drain duct (with internal diameter of at least 1.6 inches) or place it for drainage in to a sink or a tub, ensuring that there are no kinks or bends. The free end must be at a height of at least 20” from the floor (max 31.5”), the hose must be fixed in the appropriate hook on the upper part of the back panel (see figure below)

U-Connector

The end of the outlet hose must be passed through the U-Connector (included). This creates an upside-down U which is put into the drain pipe or over the edge of the sink. Failure to use the U-Connector may cause the drain hose to pop-up during drainage of the water, which may cause water damage to the surrounding area.

5

Image 5
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Unit wont fill Machine vibrating or vibrating noiseWater leaking from door Unit won’t drain out water Unit fills, won’t agitate / tumbleUnit is noisy Unit VibratesWater leaks from detergent drawer Timer doesn’t advanceWater fill in tub with unit off Unit overfillsClothes wet at the end of wash cycle Unit keeps filling only when the unit is switched onNo tumble action Clothes cold and damp at the end of dry cycleLong Drying Time Clothes hot and damp at the end of dry cyclePower Switch 52799 Replacement Procedure Replacement Procedure, Wiring & Testing of PartsDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Hot Test Cold water valve 10820 Replacement ProcedureHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Cold Test Dry Timer 50728 Replacement ProcedureHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Wiring Fusible Link Fusible Link / Wire with fuse 00807 Replacement ProcedureFEX Thermostat 00808 Replacement ProcedureFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk