Equator MD3720CEE service manual Main Motor 50751 Replacement Procedure

Page 28

17)Main Motor (50751) Replacement Procedure:

Unplug the unit.

Make sure that there is no water in the unit. Remove the back panel (3 screws at the back) Remove the belt.

Tilt the unit towards the left and carefully lay down the unit on the side. Unfix the four leveling legs and remove the bottom panel.

The motor is supported with 3 bolts, unfix the same and replace the motor. Do the wiring as before / below.

Fix all the parts back by following the reverse procedure.

Wiring: Main Motor

M4

4

8

M3

3

7

Holes for Bolts

M8

M7

M2

2 6

M6

M1

1 5

M5

Testing Procedure:

Cold Test:

1)Check the resistance between the following terminals, if the results match near about, the motor is fine.

Sr. No

Terminals

Resistance

1

1 & 2

7.8

– 8.6

2

1 & 6

2.8

– 3.4

3

2 & 6

10.6

– 12.0

4

3 & 5

9.5

– 9.8

5

5 & 7

9.5

– 9.8

6

3 & 7

13.0

– 13.6

7

4 & 8

29.4

– 31.0

e Please Note: Adjust the belt tension after replacing the motor.

28

Image 28
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Water leaking from door Machine vibrating or vibrating noiseUnit wont fill Unit fills, won’t agitate / tumble Unit won’t drain out waterUnit is noisy Unit VibratesTimer doesn’t advance Water leaks from detergent drawerWater fill in tub with unit off Unit overfillsUnit keeps filling only when the unit is switched on Clothes wet at the end of wash cycleNo tumble action Clothes cold and damp at the end of dry cycleClothes hot and damp at the end of dry cycle Long Drying TimeReplacement Procedure, Wiring & Testing of Parts Power Switch 52799 Replacement ProcedureDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Cold water valve 10820 Replacement Procedure Hot TestHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Dry Timer 50728 Replacement Procedure Cold TestHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Fusible Link / Wire with fuse 00807 Replacement Procedure Wiring Fusible LinkThermostat 00808 Replacement Procedure FEXFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk