Equator MD3720CEE service manual Half Load Switch 51799 Replacement Procedure

Page 19

8)Half Load Switch (51799) Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back)

Pull out the soap dispenser, plastic washer knob and dryer knob. Remove the control panel. (3 Screws)

Pull out the plastic switch cover for the half load switch.

Pull out the half load switch by matching the grooves in the panel pushing the switch towards the back.

Replace with the new switch and do the wiring as before / below. Fix all the parts back by following the reverse procedure.

Wiring: Half Load switch - bottom view

2

122

4

124

6 126

Testing Procedure:

Cold Test:

1)When the half load button is not pushed in – There will be continuity between the terminals 4 & 6.

2)When the half load button is pushed in – There will be continuity between the terminals 4 & 2.

19

Image 19
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Water leaking from door Machine vibrating or vibrating noiseUnit wont fill Unit Vibrates Unit fills, won’t agitate / tumbleUnit won’t drain out water Unit is noisyUnit overfills Timer doesn’t advanceWater leaks from detergent drawer Water fill in tub with unit offClothes cold and damp at the end of dry cycle Unit keeps filling only when the unit is switched onClothes wet at the end of wash cycle No tumble actionLong Drying Time Clothes hot and damp at the end of dry cyclePower Switch 52799 Replacement Procedure Replacement Procedure, Wiring & Testing of PartsDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Hot Test Cold water valve 10820 Replacement ProcedureHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Cold Test Dry Timer 50728 Replacement ProcedureHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Wiring Fusible Link Fusible Link / Wire with fuse 00807 Replacement ProcedureFEX Thermostat 00808 Replacement ProcedureFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk