Equator MD3720CEE service manual Cold water valve 10820 Replacement Procedure, Hot Test

Page 15

4)Cold water valve (10820) Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back)

Unfix the two screws at the back which hold the cold water valve.(Marked C) Remove the clamps to the two hoses.

Replace with the new valve and do the wiring as before / below. Fix all the parts back by following the reverse procedure.

Wiring: Cold water Valve

EVAX

EVA

EVFX

EVF

Testing Procedure:

Hot Test:

1)Set the washer knob to the Towels / Sheets position and switch on the unit.

2)You should get 115V AC across the terminals EVFX & EVF and the unit should start filling in with water, it the unit does not start filling the valve is bad.

3)Set the washer knob to the off position and the dryer knob to 60 and switch on the unit.

4)You should get 115V AC across the terminals EVA & EVAX.

ePlease Note: The door should be locked properly and there should be enough pressure to the water supply.

15

Image 15
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Machine vibrating or vibrating noise Water leaking from doorUnit wont fill Unit Vibrates Unit fills, won’t agitate / tumbleUnit won’t drain out water Unit is noisyUnit overfills Timer doesn’t advanceWater leaks from detergent drawer Water fill in tub with unit offClothes cold and damp at the end of dry cycle Unit keeps filling only when the unit is switched onClothes wet at the end of wash cycle No tumble actionLong Drying Time Clothes hot and damp at the end of dry cyclePower Switch 52799 Replacement Procedure Replacement Procedure, Wiring & Testing of PartsDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Hot Test Cold water valve 10820 Replacement ProcedureHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Cold Test Dry Timer 50728 Replacement ProcedureHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Wiring Fusible Link Fusible Link / Wire with fuse 00807 Replacement ProcedureFEX Thermostat 00808 Replacement ProcedureFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk