14)Heating Element (00745) Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back) The heating element is located inside the heater housing. Unfix the support to the hater housing. (4 bolts on the top) Unfix the upper heater housing. (3 screws and a few clamps) Unfix the two nuts and remove the heating element. Replace the same and do the wiring as before / below.

Fix all the parts back by following the reverse procedure.

Wiring: Heating Element

One end of the fusible link

RA

Testing Procedure:

Hot Test:

1)Set the washer knob on off position and the dryer knob on 30.

2)You should get 115V AC across the terminals of the heating element.

3)Check if the unit is heating up, if so the heating element is good.

25

Image 25
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Water leaking from door Machine vibrating or vibrating noiseUnit wont fill Unit won’t drain out water Unit fills, won’t agitate / tumbleUnit is noisy Unit VibratesWater leaks from detergent drawer Timer doesn’t advanceWater fill in tub with unit off Unit overfillsClothes wet at the end of wash cycle Unit keeps filling only when the unit is switched onNo tumble action Clothes cold and damp at the end of dry cycleLong Drying Time Clothes hot and damp at the end of dry cyclePower Switch 52799 Replacement Procedure Replacement Procedure, Wiring & Testing of PartsDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Hot Test Cold water valve 10820 Replacement ProcedureHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Cold Test Dry Timer 50728 Replacement ProcedureHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Wiring Fusible Link Fusible Link / Wire with fuse 00807 Replacement ProcedureFEX Thermostat 00808 Replacement ProcedureFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk