Equator MD3720CEE service manual Drain Pump 00776 Replacement Procedure

Page 27

16)Drain Pump (00776) Replacement Procedure:

Unplug the unit.

Make sure that there is no water in the unit. Carefully pull out the kick plate.

Tilt the unit towards the left and carefully lay down the unit on the side. Unfix the four leveling legs and remove the bottom panel.

Remove the clamps to the two hoses on the drain pump.

Unfix the 4 screws that hold the drain pump to the cabinet and replace the same. Do the wiring as before / below.

Fix all the parts back by following the reverse procedure.

Wiring: Drain pump

PSL

PSN

Testing Procedure:

Hot Test:

1)Set the washer knob to a position one click away from the off position and switch on the unit.

2)The drain pump should receive 115V AC supply and should start working.

3)If the drain pump is working it is fine or else the drain pump is bad.

27

Image 27
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Machine vibrating or vibrating noise Water leaking from doorUnit wont fill Unit Vibrates Unit fills, won’t agitate / tumbleUnit won’t drain out water Unit is noisyUnit overfills Timer doesn’t advanceWater leaks from detergent drawer Water fill in tub with unit offClothes cold and damp at the end of dry cycle Unit keeps filling only when the unit is switched onClothes wet at the end of wash cycle No tumble actionLong Drying Time Clothes hot and damp at the end of dry cyclePower Switch 52799 Replacement Procedure Replacement Procedure, Wiring & Testing of PartsDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Hot Test Cold water valve 10820 Replacement ProcedureHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Cold Test Dry Timer 50728 Replacement ProcedureHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Wiring Fusible Link Fusible Link / Wire with fuse 00807 Replacement ProcedureFEX Thermostat 00808 Replacement ProcedureFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk