Equator MD3720CEE service manual Door Switch / Door Lock 00750 Replacement Procedure

Page 13

2)Door Switch / Door Lock (00750) Replacement Procedure:

Unplug the unit.

Open the door remove the clamp to the door gasket in the front to access the door switch.

Unscrew the two screws to the door switch.

Replace with the new door switch and do the wiring as before / below. Fix all the parts back by following the reverse procedure.

Wiring: Door Switch – Back View

Latch / Slider

4

 

 

 

IPX

5

 

 

 

 

 

IP

1

2

 

3

Micro Switch

MRL

MRN

 

 

Testing Procedure:

Cold Test:

1)Push the slider towards the left (referring to the position of the door switch as in the

figure) which will operate the micro switch and check for continuity between terminals 4 & 5.

2)If there is continuity door switch is good.

ePlease Note : The terminals 4 & 5 are not marked on the door switch it is just taken for explanation.

13

Image 13
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Water leaking from door Machine vibrating or vibrating noiseUnit wont fill Unit won’t drain out water Unit fills, won’t agitate / tumbleUnit is noisy Unit VibratesWater leaks from detergent drawer Timer doesn’t advanceWater fill in tub with unit off Unit overfillsClothes wet at the end of wash cycle Unit keeps filling only when the unit is switched onNo tumble action Clothes cold and damp at the end of dry cycleLong Drying Time Clothes hot and damp at the end of dry cyclePower Switch 52799 Replacement Procedure Replacement Procedure, Wiring & Testing of PartsDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Hot Test Cold water valve 10820 Replacement ProcedureHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Cold Test Dry Timer 50728 Replacement ProcedureHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Wiring Fusible Link Fusible Link / Wire with fuse 00807 Replacement ProcedureFEX Thermostat 00808 Replacement ProcedureFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk