Maytag W10222378A Complete Installation, Check that you have all of your tools

Page 16

Complete Installation

1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2.Check that you have all of your tools.

3.Dispose of/recycle all packaging materials. Keep the plastic foam for use if the washer/dryer should be transported.

4.Check the washer/dryer’s final location. Be sure the vent is not crushed or kinked.

5.Check that the washer/dryer is level and front leveling feet are tight. See “Level Washer/Dryer.”

6.In the U.S.A.

For power supply cord installation, plug into a grounded outlet. For direct wire installation, turn on power.

In Canada

WARNING

Electrical Shock Hazard

Plug into a grounded 4 prong outlet.

Failure to do so can result in death or electrical shock.

Plug into a grounded 4 prong outlet. Turn on power.

7.Check that the water faucets are on.

8.Check for leaks around faucets and inlet hoses.

9.Remove the blue protective film on the console and any tape remaining on the washer/dryer.

10.Read the Washer/Dryer User Instructions.

11.Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.

12.To test the washer, measure 12 the normal recommended amount of detergent and pour it into the washer. Close the lid. Select HEAVY DUTY and pull out the Cycle Control knob. Allow the washer to complete one whole cycle.

13.To test the dryer, set the dryer on a full heat cycle (not an air cycle) for 20 minutes and start the dryer.

If the dryer will not start, check the following:

Controls are set in a running or “On” position. Start button has been firmly pushed. Washer/dryer is plugged into a grounded outlet. Electrical supply is connected.

Household fuses are intact and tight, or circuit breakers have not tripped.

Dryer door is closed.

14.When the dryer has been running for 5 minutes, open the dryer door and feel for heat.

If you do not feel heat, turn off the dryer and check the following:

There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.

NOTE: You may notice an odor when dryer is first heated. This odor is common when the heating element is first used. The odor will go away.

16

Image 16
Contents LAVEUSE/SÉCHEUSE Électrique DE 27 69 CM ToolsandParts AlternatePartsInstallation Clearances Mobile Home Additional Installation RequirementsWasher/Dryer Dimensions Location RequirementsDrainSystem ElectricalRequirements- U.S.AElectricalRequirements-Canada If connecting by direct wireIf your outlet looks like this Electrical Connection -U.S.A. Only UL marking on strain relief. Put the tabs of the two clampSections into the hole below the terminal block opening so Hold in place. Tighten strain relief screw enough to holdStyle 2 Direct wire strain relief Wire connection Power supply cordWire connection Direct Wire Remove center silver-colored terminal block screwConnect neutral wire white or center wire of power supply Block. Tighten screwPage VentingRequirements Vent materialInstall LevelingLegs Install the front leveling feetRemoveShippingStrap ConnecttheDrainHoseConnect the Inlet Hoses Recommended exhaust installations Optional exhaust installationsAlternate installations for close clearances SecuretheDrainHoseInstallVentSystem Special provisions for mobile home installationsVent system chart Level Washer/DryerCheck that you have all of your tools Complete InstallationIf the dryer will not start, check the following Sécurité DE LA LAVEUSE/SÉCHEUSE Outillageetpièces Pièces fourniesPièces nécessaires pour la laveuse non fournies Outillage requisExigences d’emplacement Autres piècesIl vous faudra Si vous avez Vous devrez acheterInstallation dans une maison mobile autres exigences Dimensions de la laveuse/sécheuse’installation dans une maison mobile exige Système devidangeSpécifications électriques Canada Système de vidange avec évier de buanderie illustration CSystème de vidange par le plancher illustration D ’est à l’utilisateur qu’incombe la responsabilité deExigences concernant l’évacuation Matériel pour l’évacuationLes styles de clapets recommandés sont illustrés ci-dessous Enlever la sangle d’expéditionÉvacuation Le clapet incliné illustré ici est acceptableRaccordement du tuyaude vidange Installation des pieds de nivellementRaccordement des tuyaux d’alimentation Immobilisationdu tuyau de vidange Nettoyer les conduites d’eauConnecter les tuyaux d’alimentation à la laveuse Pour un placard ou un endroit exiguInstallations d’évacuation recommandées Installations d’évacuation facultativesAutres installations où le dégagement est réduit Planification du système d’évacuationInstallation du système d’évacuation Nivellement de la laveuse/sécheuseTableau des systèmes d’évacuation Déterminer l’itinéraire d’acheminement du conduitRaccordement du conduit d’évacuation Acheverl’installationSi la sécheuse ne démarre pas, vérifier ce qui suit Page Page Page W10222378A Tous droits réservés