Maytag W10222378A Wire connection Direct Wire, Remove center silver-colored terminal block screw

Page 8

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center silver- colored terminal block screw. Tighten screw.

A B

D

CE

A.Neutral ground wire

B.Center silver-colored terminal block screw

C.External ground conductor screw

D.Neutral wire (white or center)

E.34" (19 mm) UL listed strain relief

3.Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.

D

C

B

E

AF

A.External ground conductor screw

B.Ground wire (green or bare) of power supply cord

C.Neutral ground wire

D.Center silver-colored terminal block screw

E.Neutral wire (white or center)

F. ¾" (19 mm) UL listed strain relief

4.Connect the other wires to outer terminal block screws. Tighten screws.

5.Tighten strain relief screws.

6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

7.You have completed your electrical connection. Now go to “Venting Requirements.”

4-wire connection: Direct Wire

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

Direct wire cable must have 5 ft (1.52 m) of extra length so washer/dryer can be moved if needed.

Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 112" (38 mm) from

3 remaining wires. Strip insulation back 1" (25 mm). Shape ends of wires into a hook shape.

1" (25mm)

(127

5"

mm)

 

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together, and tighten screw, as shown.

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.

AB

D

C E

A. Neutral ground wire

B. Center silver-colored terminal block screw

C. External ground conductor screw

D. Neutral wire (white or center wire)

E. ¾" (19 mm) UL listed strain relief

8

Image 8
Contents LAVEUSE/SÉCHEUSE Électrique DE 27 69 CM ToolsandParts AlternatePartsInstallation Clearances Mobile Home Additional Installation RequirementsWasher/Dryer Dimensions Location RequirementsDrainSystem ElectricalRequirements- U.S.AIf your outlet looks like this If connecting by direct wireElectricalRequirements-Canada Electrical Connection -U.S.A. Only UL marking on strain relief. Put the tabs of the two clampSections into the hole below the terminal block opening so Hold in place. Tighten strain relief screw enough to holdStyle 2 Direct wire strain relief Wire connection Power supply cordWire connection Direct Wire Remove center silver-colored terminal block screwConnect neutral wire white or center wire of power supply Block. Tighten screwPage VentingRequirements Vent materialInstall LevelingLegs Install the front leveling feetRemoveShippingStrap ConnecttheDrainHoseConnect the Inlet Hoses Recommended exhaust installations Optional exhaust installationsAlternate installations for close clearances SecuretheDrainHoseInstallVentSystem Special provisions for mobile home installationsVent system chart Level Washer/DryerIf the dryer will not start, check the following Complete InstallationCheck that you have all of your tools Sécurité DE LA LAVEUSE/SÉCHEUSE Outillageetpièces Pièces fourniesPièces nécessaires pour la laveuse non fournies Outillage requisExigences d’emplacement Autres piècesIl vous faudra Si vous avez Vous devrez acheterInstallation dans une maison mobile autres exigences Dimensions de la laveuse/sécheuse’installation dans une maison mobile exige Système devidangeSpécifications électriques Canada Système de vidange avec évier de buanderie illustration CSystème de vidange par le plancher illustration D ’est à l’utilisateur qu’incombe la responsabilité deExigences concernant l’évacuation Matériel pour l’évacuationLes styles de clapets recommandés sont illustrés ci-dessous Enlever la sangle d’expéditionÉvacuation Le clapet incliné illustré ici est acceptableRaccordement des tuyaux d’alimentation Installation des pieds de nivellementRaccordement du tuyaude vidange Immobilisationdu tuyau de vidange Nettoyer les conduites d’eauConnecter les tuyaux d’alimentation à la laveuse Pour un placard ou un endroit exiguInstallations d’évacuation recommandées Installations d’évacuation facultativesAutres installations où le dégagement est réduit Planification du système d’évacuationInstallation du système d’évacuation Nivellement de la laveuse/sécheuseTableau des systèmes d’évacuation Déterminer l’itinéraire d’acheminement du conduitSi la sécheuse ne démarre pas, vérifier ce qui suit Acheverl’installationRaccordement du conduit d’évacuation Page Page Page W10222378A Tous droits réservés