Maytag W10222378A Electrical Connection -U.S.A. Only, Two clamp sections together

Page 6

Electrical Connection -U.S.A. Only

Power Supply Cord

 

Direct Wire

 

 

 

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

WARNING

Fire Hazard

Use 10 gauge solid copper wire. Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

1.

Disconnect power.

3. Install strain relief.

2.

Remove the hold-down screw and terminal block cover.

Style 1: Power supply cord strain relief

A

 

Remove the screws from a 34" (19 mm) UL listed strain relief

 

 

(UL marking on strain relief). Put the tabs of the two clamp

 

 

sections into the hole below the terminal block opening so

 

 

that one tab is pointing up and the other is pointing down, and

 

B

hold in place. Tighten strain relief screw enough to hold the

 

two clamp sections together.

 

C

A

 

 

 

 

B

 

 

C

E

D

D

A. Strain relief tab pointing up

A. Center silver-colored terminal block screw

B. Hole below terminal block opening

B. Hold-down screw

 

 

C. Clamp section

C. Terminal block cover

 

 

D. Strain relief tab pointing down

D. Neutral ground wire

 

 

 

E. External ground conductor screw

 

 

6

Image 6
Contents LAVEUSE/SÉCHEUSE Électrique DE 27 69 CM ToolsandParts AlternatePartsWasher/Dryer Dimensions Installation ClearancesMobile Home Additional Installation Requirements Location RequirementsDrainSystem ElectricalRequirements- U.S.AIf connecting by direct wire ElectricalRequirements-CanadaIf your outlet looks like this Sections into the hole below the terminal block opening so Electrical Connection -U.S.A. OnlyUL marking on strain relief. Put the tabs of the two clamp Hold in place. Tighten strain relief screw enough to holdStyle 2 Direct wire strain relief Wire connection Power supply cordWire connection Direct Wire Remove center silver-colored terminal block screwConnect neutral wire white or center wire of power supply Block. Tighten screwPage VentingRequirements Vent materialRemoveShippingStrap Install LevelingLegsInstall the front leveling feet ConnecttheDrainHoseConnect the Inlet Hoses Alternate installations for close clearances Recommended exhaust installationsOptional exhaust installations SecuretheDrainHoseVent system chart InstallVentSystemSpecial provisions for mobile home installations Level Washer/DryerComplete Installation Check that you have all of your toolsIf the dryer will not start, check the following Sécurité DE LA LAVEUSE/SÉCHEUSE Pièces nécessaires pour la laveuse non fournies OutillageetpiècesPièces fournies Outillage requisIl vous faudra Exigences d’emplacementAutres pièces Si vous avez Vous devrez acheter’installation dans une maison mobile exige Installation dans une maison mobile autres exigencesDimensions de la laveuse/sécheuse Système devidangeSystème de vidange par le plancher illustration D Spécifications électriques CanadaSystème de vidange avec évier de buanderie illustration C ’est à l’utilisateur qu’incombe la responsabilité deExigences concernant l’évacuation Matériel pour l’évacuationÉvacuation Les styles de clapets recommandés sont illustrés ci-dessousEnlever la sangle d’expédition Le clapet incliné illustré ici est acceptableInstallation des pieds de nivellement Raccordement du tuyaude vidangeRaccordement des tuyaux d’alimentation Connecter les tuyaux d’alimentation à la laveuse Immobilisationdu tuyau de vidangeNettoyer les conduites d’eau Pour un placard ou un endroit exiguAutres installations où le dégagement est réduit Installations d’évacuation recommandéesInstallations d’évacuation facultatives Planification du système d’évacuationTableau des systèmes d’évacuation Installation du système d’évacuationNivellement de la laveuse/sécheuse Déterminer l’itinéraire d’acheminement du conduitAcheverl’installation Raccordement du conduit d’évacuationSi la sécheuse ne démarre pas, vérifier ce qui suit Page Page Page W10222378A Tous droits réservés