Maytag W10222378A ElectricalRequirements-Canada, If your outlet looks like this

Page 5

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.

10-gauge solid copper wire (do not use aluminum). At least 5 ft (1.52 m) long.

For a grounded, cord-connected washer/dryer: This washer/dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This washer/dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

For a permanently connected washer/dryer:

This washer/dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the washer/dryer.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the washer/dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

ElectricalRequirements-Canada

WARNING

Electrical Shock Hazard

Plug into a grounded 4 prong outlet.

Failure to do so can result in death or electrical shock.

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1-latest edition and local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

To supply the required 4 wire, single phase, 120/240 volt,

60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.

4-wire receptacle 14-30R

Do not use an extension cord.

If you are using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317. For further information, please reference the service numbers located in the Washer/Dryer User Instructions.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected washer/dryer: This washer/dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This washer/dryer is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the washer/dryer is properly grounded. Do not modify the plug provided with the washer/dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

5

Image 5
Contents LAVEUSE/SÉCHEUSE Électrique DE 27 69 CM AlternateParts ToolsandPartsMobile Home Additional Installation Requirements Installation ClearancesWasher/Dryer Dimensions Location RequirementsElectricalRequirements- U.S.A DrainSystemIf your outlet looks like this If connecting by direct wireElectricalRequirements-Canada UL marking on strain relief. Put the tabs of the two clamp Electrical Connection -U.S.A. OnlySections into the hole below the terminal block opening so Hold in place. Tighten strain relief screw enough to holdWire connection Power supply cord Style 2 Direct wire strain reliefRemove center silver-colored terminal block screw Wire connection Direct WireBlock. Tighten screw Connect neutral wire white or center wire of power supplyPage Vent material VentingRequirementsInstall the front leveling feet Install LevelingLegsRemoveShippingStrap ConnecttheDrainHoseConnect the Inlet Hoses Optional exhaust installations Recommended exhaust installationsAlternate installations for close clearances SecuretheDrainHoseSpecial provisions for mobile home installations InstallVentSystemVent system chart Level Washer/DryerIf the dryer will not start, check the following Complete InstallationCheck that you have all of your tools Sécurité DE LA LAVEUSE/SÉCHEUSE Pièces fournies OutillageetpiècesPièces nécessaires pour la laveuse non fournies Outillage requisAutres pièces Exigences d’emplacementIl vous faudra Si vous avez Vous devrez acheterDimensions de la laveuse/sécheuse Installation dans une maison mobile autres exigences’installation dans une maison mobile exige Système devidangeSystème de vidange avec évier de buanderie illustration C Spécifications électriques CanadaSystème de vidange par le plancher illustration D ’est à l’utilisateur qu’incombe la responsabilité deMatériel pour l’évacuation Exigences concernant l’évacuationEnlever la sangle d’expédition Les styles de clapets recommandés sont illustrés ci-dessousÉvacuation Le clapet incliné illustré ici est acceptableRaccordement des tuyaux d’alimentation Installation des pieds de nivellementRaccordement du tuyaude vidange Nettoyer les conduites d’eau Immobilisationdu tuyau de vidangeConnecter les tuyaux d’alimentation à la laveuse Pour un placard ou un endroit exiguInstallations d’évacuation facultatives Installations d’évacuation recommandéesAutres installations où le dégagement est réduit Planification du système d’évacuationNivellement de la laveuse/sécheuse Installation du système d’évacuationTableau des systèmes d’évacuation Déterminer l’itinéraire d’acheminement du conduitSi la sécheuse ne démarre pas, vérifier ce qui suit Acheverl’installationRaccordement du conduit d’évacuation Page Page Page Tous droits réservés W10222378A