Dryer Dimensions

50W'

128.27 cm)

ExplosionHazard

Keepflammablematerialsandvapors,suchas

gasemine,awayfromdryer.

Placedryeratleast18inches(48cm)abovethefloor

foragarageinstallation.

Faimure to do so can resuJt in death, e×plosion, or fire.

You will need

A location that allows for proper exhaust installation. See "Venting Requirements."

A separate30-amp circuit.

A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements."

A sturdy floor to support the total dryer weight of 200 Ibs (90.7 kg). The combined weight of a companion appliance should also be considered.

A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. (If slope is greater than 1" [2.5 cm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor. If using a pedestal, you will need an additional 6" (15.24 cm).

Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to open fully.

"311/2"

(80.01cm)

27"

Js._\ -.S-t (_8_6ore)

*Most installations require a minimum 51/2''(14 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements."

Minimum installation spacing for recessed area, custom undercounter or closet installation

The following dimensions shown are for the minimum spacing allowed.

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing of 1" (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

,0o:2tt

I

0" _ 27" ' 0"

(oom)- (68.6 om-F l<--(6

Image 6
Contents Sears Canada Inc., Toronto, Ontario, Canada M5B 2B8 8563627Table of Contents Maintenance AgreementsWarranty Pedestal Option WarrantyDryer Safety Safety iNSTRUCTiONSPedestal Color Part Height Parts suppliedParts needed 15.5Custom undercounter installation Dryer only ForagarageinstallationInstallation clearances You will needRecessed or closet installation Dryer on pedestal To contact a qualified electrical installerCloset installation Dryer only Mobile home additional installation requirementsSave These INSTRUOTmONS Typical exhaust installationsGROUNDmNG Instructions Exhausted OutdoorsTypeof hood Recommended hood styles are shown here Hoods Rigid metal Vent Length Chart Number Type Box or Angled TurnsHoods FlexibleDryer De net remove Dryer door Reverse the door handle Dryer USE To make changes during an Auto Dry CycleDry most loads using the preset cycle settings Control Locked light glows when this option is enabled Wrin KLE GuardBULKY/BEDDING Heavy DutyTimed DRY JeansAir Dry When using Air DryEnd of Cycle Signal Type of Load TimeEvery load cleaning Suggested Items for Rack TemperatureDrying Setting Time Minutes To cleanMoving cars For power supply cord-connected dryers As needed cleaningTo clean dryer drum To washTroubleshooting Did load overdry? Items shrinking Was the dryer overloaded?Did the load overdry? Is the dryer being used for the first time?Table DES Matii RES Contrats DentretienGarantie Garantie DU PII Destal FacultatifSI Curiti DE LA SI Cheuse IMPORTANTES INSTRUCTiONS DE SECURiTECONSERVEZCESiNSTRUCTiONS Instructions Dinstallation Pices fourniesPieces ncessaires Dimensions de la scheuse Espacements d installationOn a besoin I0 31!/2-I01 I0 31v2-ICommuniquer avec un electricien qualifi Installations typiques dvacuation Instructions DE Uajson a LA TerreInstallations facultatives dvacuation Autres installations ou le dgagement est r6duitGraphite Bisque Ments de Direction Persiennes Coudes Dtermination de la Iongueur du conduitChange Conduit Type boite SoupleScheuse Ne pas enver Pordeb scheuse Rinstallation de la porte Inverser la charnire et le couvre-charniereInverser la poign6e de la porte Si la scheuse ne dmarre pas, vrifier ce qui suit Utilisation DE LA SI Cheuse Pour effectuer des changements durant un programmeAppuyer sur PAUSE/CANCELdeux fois ou ouvrir la porte Conseils pour les programmes Control Locked Verrouillage des commandesConseils de schage Wet MouillCasual Timed Signal de fin de programme Changement des programmes aprs avoir appuy sur StartUtilisation de la grille de schage avec chaleur SI Cheuse Nettoyage & chaque chargeNettoyage Dans le conduit dvacuation Precautions & prendre avant un dmnagementDans la caisse de la scheuse Nettoyage du tambour de la scheuseChangement de rampoule du tambour Schage insatisfaisant des v6tements Vrifier ce qui suitLa scheuse ne fonctionne pas Vrifier ce qui suit Rtrcissement des articles Charpie sur la chargeLa charge a-t-elle t sche a Iexcs? Le linge a-t-il t sch a Iexcs?MY-HOME