Minimum installation spacing for recessed or closet installation, with or without a pedestal
■The dimensions shown are for the minimum spacing allowed.
■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Closet installation - Dryer only
|
|
|
|
| 3" |
| 14" max. |
|
| (7.6 cm) | |
| (35.6 cm) | 48 in.2 |
|
| |
|
|
| (310 cm2) |
| |
| 18" min. |
|
|
| |
| (45.72 cm) |
|
|
| |
|
|
| 24 in.2 | 2) |
|
|
|
| (155 cm | 3" | |
|
|
|
|
| |
|
|
|
|
| (7.6 cm) |
0" | 31½" | 0" |
|
|
|
(0 cm) (80 cm) | (0 cm) |
|
|
| |
| A |
|
|
| B |
A. Side view - closet or confined area
B. Closet door with vents
Recessed or closet installation - Dryer on pedestal
|
|
|
| 14" max. | |
|
|
|
| (35.6 cm) | |
|
|
|
| 18" min. | |
|
|
|
| (45.72 cm) | |
0" | 27" | 0" | 0" | 31½" | 0" |
(0 cm) | (68.6 cm) | (0 cm) | (0 cm) | (80 cm) | (0 cm) |
AB
A. Recessed area
B. Side view - closet or confined area
Minimum installation spacing for cabinet installation
■The dimensions shown are for the minimum spacing allowed.
■For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.
7" (17.8 cm) | 7" (17.8 cm) |
9"
(22.9 cm)
0" | 31¹ " | 0" | 0" | 27" | 0" |
(0 cm) | (80.0 cm) | (0 cm) | (0 cm) | (68.6 cm) (0 cm) |
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The install- ation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard
Mobile home installations require:
■Metal exhaust system hardware which is available for purchase from your dealer.
■Mobile home Installation Kit Part Number 346764. See “Tools and Parts” section for ordering information.
■Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
6