1. Turn the gas supply o by moving the
Closed Valve | A |
| |
Open Valve | B |
2.Disconnect and discard old ßexible gas connector. Replace with a new CSA(AGA) approved ßexible gas connector.
3.Remove the shipping cap from the gas inlet pipe at the rear of the dryer.
4.Connect a !" NPT elbow to the gas inlet pipe on the dryer. Then connect a ßare adapter to the elbow.
IMPORTANT: Use a pipe wrench to keep the dryer gas inlet pipe from twisting.
Gas Inlet Pipe on |
|
|
the Dryer |
|
|
³⁄₈" NPT Elbow | A | C |
³⁄₈" NPT Flare Adapter |
| B |
|
|
5.Connect the dryer to the gas supply line with a ßexible gas connector.
Flexible Gas Connector | A |
6.Tighten the ßexible gas connector using two adjustable wrenches.
7. Turn the gas supply on by moving the
17