American Dryer Corp ADS-464 manual

Page 59

-Check fuse 10’s blown fuse indicator

-Check wiring; refer to ADS-464 Main Panel Wiring Diagram

-Re-Test

7.“DRUM FAULT” Message

PLC (PROGRAMMABLE LOGIC CONTROLLER) MESSAGE “DRUM FAULT” a. PROBABLE CAUSE;

1.Stop motion detector module or sensor. With control voltage “ON” (green push-button), use the pendant control in “LOAD POSITION” to rotate the tumbler.

Note input #0, 10 on the PLC, stop the tumbler and wait for device’s latched relay to de-energize. The time from when the tumbler stopped to the relay de- energizing should be 15-20 seconds.

-If the de-energizing time is satisfactory, the unit is operating correctly

-Check circiut wiring, and Re-Test (refer to ADS-464 Main Panel Wiring Diagram)

-If the de-energizing time is incorrect:

-Adjust the “time adjust” on the stop motion detector module and re-test

If the input # 0, 10 on the PLC is not on after several rotations of the tumbler:

-Check fuse 2 and replace if necessary.

-Rotate the tumbler using the pendant control in “LOAD POSITION.” Does the module’s L.E.D. respond?

-If “YES,” adjust the “sense time” until the L.E.D. (light emitting diode) stays on for 15-20 seconds after tumbler stops, then refer to section 1 above

-If “NO,” check:

-Inductive proximity sensor for damage

-Sensor distance from targets is 3/16’. The proximity sensor is located in the same area as the tumbler junction box.

-Inductive proximity adjustment

-Tumbler target

-Stop motion detector module

-Circiut wiring; refer to ADS-464 main panel wiring diagram ADS-464 tumbler junction box wiring diagram

55

Image 59
Contents ADS-464 Installation/Operators Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Pour Votre SécuritéFor Your Safety Page Table of Contents Service Parts Important Information SectionExplosion could Result Safety PrecautionsPage Specifications SPECIFICATIONS/DIMENSIONSDimensions Reassembly of Dryer Installation ProceduresPage Page Location Requirements Internal AIR, Electrical and Water Connections Page Page Page Page Page External Supply Connections Page MAN2371 Page Latest Edition Electrical RequirementsDedicated Sprinkler Service Electrical Service Specifications PER DryerPage Fresh AIR Supply Requirements 900 kg/hr Steam InformationShut Down Instructions Preparation for Operation PRE START-UPSuggested Cleaning Schedule Routine MaintenanceCleaning Monthly Tumbler Basket Support and Drive System Component System DescriptionsPage Page Main AIR Blower and Heat Reclaimer System Heat Reclaim ER Settings Compressed AIR System Page Internal and External Pilot Air Supply Safety Devices Door Open Parts SERVICE/PARTS InformationService Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Standards TroubleshootingProbable Causes Power MalfunctionsNo Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off Sprinkler Circuit Components 3CRB Not UsedSprinkler Circuit Description Page ADS-464 on button does respond Possible Solutions Unless the Water Valve to the Sprinkler is Closed General DescriptionPage Page Introduction Tumbler Section Electrical MalfunctionsPage Rear Panel Control Problems Emergency Stop E-Stop Function Drum Forward and Reverse Function PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UP DS1-B=LOAD Door Switch DS2-B=UNLOAD Door Switch Probable Solutions Page Base Section Electrical Malfunctions LS1-B=FRONT Down Switch LS2-B=REAR Down Switch Lint Screen Must be Cleaned Every Five 5 Drying Cycles Clogged Lint Screen or Lint BAG AIR Pressure Setting SEL a = Load SEL B = Unload Pendant Control MalfunctionsTumbler Forward Pendant --- PB1 Fuse 4 on Main Electrical Panel Faulty Switches Temperature Sensing Exhaust Dsfl Message a Probable Causes Temperature Sensing Component DescriptionsDefective Analog Input Module or Channel Motors Circuit Wiring to the Analog Input ModuleProbable Solutions ADS-464 Idling ADS-464 Running ADC 06/18/96-3 06/24/96-25 11/12/99-20