2Rear Panel Control Problems EMERGENCY STOP (E-Stop) Function
a)PROBABLE CAUSES:
1.Rear panel disconnect plug
2.Defective switch
3.Wiring back to the main electrical enclosure
b)POSSIBLE SOLUTIONS;
1.If the EMERGENCY STOP
-Verify that ALL other EMERGENCY STOP
-Verify that the rear panel’s disconnect plug is indeed connected. The disconnect plug is to allow the removal of the panel for dryer servicing
2.Defective EMERGENCY STOP
-Shut power off (main breaker) remove the rear panel and check switch using an OHM meter; replace if defective
-
3.Wiring back to main electrical enclosure
-Shut power off to the
-Open “disconnects” on terminal 16 and terminal 17 of TB1; These disconnects are located on the bottom of the main electrical enclosure.
-Connect an OHM meter to the output side of terminal 16 and terminal 17 of TB1
-Push in the Emergency Stop
-Does the previous test show that there is a switch closure opening?
-If “YES,” refer to section 3a
-If “NO,” refer to section 3b
3a) Wiring from the Emergency Stop button to the main electrical enclosure is okay.
-Check REAR PANEL CONTROLS WIRING DIAGRAM
-Check TUMBLER JUNCTION BOX WIRING DIAGRAM
-Refer to section a above and