-If “NO,” check associated:
-Switch and Wiring
-Check wiring back to the base electrical junction box
-Check PLC (Programmable Logic Controller)
-Refer toblueprints: Main Electrical Panel Diagram, Base Electrical Junction Box Wiring Diagram
-
1b) Place the
-Actuate the Rear Down Switch by hand
-Have someone verify that PLC (Programmable Logic Controller) input L.E.D. #12 lights when the switch actuator is down, and is OFF when the actuator is up
-Does L.E.D. #12 come “ON” when the switch is down?
-If “YES,” wiring is OK
-Check switch, actuator placement and tilt actuation
NOTE: If actuator is at 90ºor greater angle with the base, the actuator will be damaged if machine is lowered.
-If “NO,” check assoicated:
-Switch and wiring
-Check wiring back to the base electrical junction box
-Check PLC (Programmable Logic Controller)
-Refer to blueprints: Main Elecrtical Panel Diagram, Base Electrical Junction Box Wiring Diagram
-
3.0Lint Screen Mechanism Problem “SCREEN FAULT”
A “SCREEN FAULT” message is generated by the incorrect state of the lint screen mehanism sensor switch. The following information will address the correct signal, since it is associated with the Base Electrical Junction Box.
a)PROBABLE CAUSES
1.THE LINT SCREEN MUST BE CLEANED EVERY FIVE (5) DRYING CYCLES
66