Maytag W10150639A Gas Supply Requirements, Gas Type, Gas supply line, Burner input requirements

Page 9

Gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

If you are using Natural gas, do not use copper tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.

If your dryer has been converted to use LP gas, ³⁄₈" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.

Must include a shutoff valve:

In the U.S.A.:

An individual manual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.

In Canada:

An individual manual shutoff valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shutoff valve be installed within six (6) feet (1.8 m) of the dryer. The location should be easy to reach for opening and closing.

A C E

BD

Gas Type

Natural gas:

This dryer is equipped for use with Natural gas. It is design-certified by CSA International for LP (propane or butane) gases with appropriate conversion.

Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section.

LP gas conversion:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.

A. ³⁄₈" flexible gas connector

B. ³⁄₈" pipe to flare adapter fitting

C. ¹⁄₈" NPT minimum plugged tapping

D. ½" NPT gas supply line

E. Gas shutoff valve

Gas supply connection requirements

Use an elbow and a ³⁄₈" flare x ³⁄₈" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.

Use only pipe-joint compound. Do not use TEFLON®† tape.

This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.

Gas supply line

Must include ¹⁄₈" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer. See illustration.

¹⁄₂" IPS pipe is recommended.

³⁄₈" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.

Burner input requirements

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

9

Image 9
Contents W10150638A Sécheuse À GAZTable DES Matières Table of ContentsYour safety and the safety of others are very important Dryer SafetyImportant Safety Instructions Installation Instructions Tools and PartsOptional Pedestal Dryer Dimensions Installation clearancesCustom undercounter installation Dryer only Location RequirementsCloset installation Dryer only Recommended installation spacing for cabinet installationRecessed or closet installation Dryer on pedestal Cabinet are requiredMobile home installations require Mobile home Additional installation requirementsElectrical Requirements Required spacingGas Type Gas Supply RequirementsGas supply line Burner input requirementsIf using an existing vent system Gas supply pressure testingVenting Requirements Dryer gas pipePlan Vent System Optional exhaust installationsClamps ExhaustAlternate installations for close clearances Special provisions for mobile home installationsDetermine vent path Install Leveling Legs Install Vent SystemVent system chart Make Gas ConnectionReverse Door Swing Level DryerConnect Vent Remove the doorReverse the hinge and hinge bracket Reinstalling the doorComplete Installation Style 1 Remove the plug stripStyle 2 Remove the label If the dryer will not start, check the following Dryer USETo use an Automatic Cycle Starting Your DryerHow Automatic Cycles Work To use a Manual CycleStopping Your Dryer Pausing or RestartingControl Locked Drying and Cycle TipsCycles Drying Rack Additional FeaturesCleaning the Lint Screen Cleaning the Dryer LocationEvery load cleaning Dyer CareRemoving Accumulated Lint Cleaning the Dryer InteriorVacation and Moving Care Changing the Drum LightTroubleshooting Dryer OperationDryer Results Lint on load Cycle time too shortStains on load or drum Loads are wrinkledAccessories Assistance or ServiceU.S.A CanadaONE Year Limited Warranty Maytag Corporation Major Appliance WarrantyPage Votre sécurité et celle des autres est très importante Sécurité DE LA SécheuseImportantes Instructions DE Sécurité Instructions D’INSTALLATION Outillage et piècesPiédestal facultatif Dimensions de la sécheuse Exigences d’emplacementIl vous faudra Dégagements de séparation à respecterEspacement recommandé pour linstallation dans un placard Installation dans un placard Sécheuse seulement’entrée d’air au sommet du placard Spécifications électriques Linstallation dans une maison mobile exigeCanalisation d’arrivée de gaz Type de gazGaz naturel Exigences concernant le raccordement au gazCaractéristiques d’alimentation du brûleur Exigences concernant lévacuationCanalisation d’arrivée de gaz de la sécheuse En cas dutilisation du système dévacuation existantConduit métallique flexible Conduit métallique rigideCoudes Brides de serrageInstallations d’évacuation facultatives Autres installations où le dégagement est réduitPlanification du système d’évacuation Installation des pieds de nivellement Installation du système d’évacuationDéterminer litinéraire dacheminement du conduit Tableau des systèmes dévacuationUtilisation dans une maison mobile Raccordement au gazMise à niveau de la sécheuse Raccordement du conduit d’évacuationInversion du sens douverture de la porte Enlever la porteRéinstallation de la porte Inverser la charnière et son supportStyle 2 Retirer l’étiquette Si la sécheuse ne démarre pas, vérifier ce qui suit Achever l’installationUtilisation DE LA Sécheuse Mise en marche de la sécheuseUtilisation dun programme automatique Pause ou remise en marche Arrêt de la sécheusePour arrêter la sécheuse à n’importe quel moment Pour mettre la sécheuse en pause à nimporte quel momentVerrouillage des commandes Conseils pour le séchage et les programmesTémoins lumineux Programmes Caractéristiques supplémentaires Cycle End Signal signal de fin de programme Grille de séchageUtilisation de la grille de séchage Entretien DE LA Sécheuse Nettoyage de lemplacement de la sécheuseNettoyage du filtre à charpie Nettoyage à chaque chargeRetrait de la charpie accumulée Nettoyage de l’intérieur de la sécheuseDéménagement Changement de l’ampoule d’éclairage Du tambourDépannage Fonctionnement de la sécheuseRésultats de la sécheuse Charpie sur la charge Temps de programme trop courtTaches sur la charge ou sur le tambour Charges froisséesAccessoires Assistance OU ServiceAu Canada Si vous avez besoin de pièces de rechangeGarantie DES Gros Appareils Ménagers Maytag Corporation Tous droits réservés W10150638A SP PN W10150639A