Teledyne API Model 465L O3 Monitor Operation Manual

 

Analog Output, Voltage Mode

 

0 - 5V

 

Isolated Analog Output, 4-

 

Maximum voltage between outputs and ground

 

20mA Mode

 

60V peak

 

System OK Status Relay

 

SPDT (Form C) Dry Contact, 250 VAC, 5A

 

 

 

SPDT (Form C) Dry Contact, 250 VAC, 5A (x2,

 

Global Alarm Relays

 

HI and HI-HI)

 

 

 

6 - SPST Dry Contact, 50VDC, 250mA Resistive

 

Instrument Status Outputs

 

Load

Multi-Stream Specifications:

 

 

 

Minimum Stream Duration

 

 

 

(Cycle Time)

 

1.0 min

 

Stream Alarm Relays (HI and

 

SPST Dry Contact, 50VDC, 250mA Resistive

 

HI-HI)

 

Load (2 per stream)

 

 

 

SPST Dry Contact, 50VDC, 250mA Resistive

 

Stream ID Relays

 

Load (1 per stream)

2.2.Approvals

This section presents Safety and Electromagnetic Compatibility (EMC) compliance approvals for the Model 465L monitor.

2.2.1.Safety

IEC 61010-1:2001, Safety requirements for electrical equipment for measurement, control, and laboratory use.

CE: 2006/95/EC, Low-Voltage Directive

North American:

cNEMKO (Canada): CAN/CSA-C22.2 No. 61010-1-04

NEMKO-CCL (US): UL No. 61010-1 (2nd Edition)

2.2.2.EMC

EN 61326-1 (IEC 61326-1), Class A Emissions/Industrial Immunity

EN 55011 (CISPR 11), Group 1, Class A Emissions

FCC 47 CFR Part 15B, Class A Emissions

CE: 2004/108/EC, Electromagnetic Compatibility Directive

16

05509F DCN6409

Image 18
Contents Model 465L Ozone Monitor Page About Teledyne Advanced Pollution Instrumentation Tapi This page intentionally left blank Important Safety Information General Safety HazardConsignes DE Sécurité Mise EN GardeAbout this Manual Part Name/Description NumberRevision History Table of Contents Digital Communications Figures Sensor Detail Tables Xii 05509F DCN6409 Introduction PrefaceThis page intentionally left blank Specifications and Agency Approvals SpecificationsApprovals SafetyMulti-Stream Specifications EMCOther Type Certifications PhoneThis page intentionally left blank Principle of Operation = − InHg × ln ×  27305509F DCN6409 Getting Started Nema AC Power Connection to Monitor Pneumatic Connections, Rack Mount Configuration Pneumatic ConnectionsPneumatic Connections, Nema Configuration, Multi-Stream Sample Gas ConnectionSample Filtration Sample System Design in Humid Environments05509F DCN6409 Sample Conditioner Option Permeation Gas Dryer OptionExhaust Connection Rear Panel Electrical I/O ConnectionsAnalog Output Location of I/O Connectors in the Nema ConfigurationElectrical I/O Connections Status OutputsStatus Output Schematic Status Name Normal Operating Output # StateRelay # Function Hi-Current Relay OutputsRelay # Function Normal Operating State Normal Operating StateMulti-Stream Relay Outputs Optional Relay # Function Meaning6.2. RS485 Connection Digital Serial Interfaces6.1. RS232 Connection Ethernet ConnectionHis page intentionally left blank Frequently Asked Questions This page intentionally left blank Options 05509F DCN6409 Ozone Concentration Display OperationFront Panel Overview Menu Navigation KeypadConcentration Alarm Status/Reset Alarm Status LED Color Alarm StateStream Selector Status/Control Optional Menu Navigation Basics Status LEDsFront Panel Menus Status LED Normal StateEditing Numeric Values Front Panel Menu Diagram OFF Diag Menu Analog Step-TestPoint 5V Output MA Output Signal I/O Signal Name Rear Panel Label FunctionMemory Reset Zero CalibrationSpan Calibration Flow Calibration Optional Electronic Flowmeter only Span Cal MenuFlow Cal Menu Parameter Meaning Config MenuView Menu UnitsSETUP-VARS Menu CountSETUP-STREAM Menu Property Meaning Default Range ValueMulti-Stream Operation Changing Com Port Hardware Configuration Digital CommunicationsDigital Communications Overview RS232 Configuration RS-232 Configuration Function DB-9 General I/O Connector Pin SW2 DTE SW2 DCEProperty Value RS-485 Configuration Function DB-9 General I/O Connector Pin SW2 DCEVerifying Network Hardware Connection Ethernet ConfigurationHardware Setup for Configuring the Ethernet Module Link LED Left Side Activity LED Right Side Color MeaningDetermining a Dynamically Assigned IP Address Dhcp Mode Manually Assigning a Static IP AddressDescription Modbus Commands SupportedModbus Register Maps Function CodeReal-Time Concentration and Status Registers Read Only Decimal Address Description Register Type Start Bit # BitsInstrument Setup and Configuration Registers Read / Write Decimal Address Description Register Type Start Bit # Bits This page intentionally left blank Maintenance and Adjustments Maintenance ScheduleMaintenance Item Recommended Interval Section Instrument Layout, Rack Mount Configuration Instrument LayoutInstrument Layout, Nema Configuration Replacing Internal Particulate FilterUV Lamp Adjustment UV Lamp Replacement Sample Pump Replacement05509F DCN6409 Sensor Valve Replacement Sensor DetailWater Drop-Out Filter Option Maintenance Configuring the Analog OutputCleaning Exterior Surfaces of the M465L Boot Loader OperationBoot Loader Hardware Setup Boot Loader Software SetupUpload Firmware Verify Firmware This page intentionally left blank Troubleshooting Pneumatic DiagramReference Drawings Interconnect Diagram RACK-MOUNT Version onlyStatus LED/Output Definitions Invalid Reading Pneumatic ErrorSensor OK Check LampPressure Too High Pressure Too LowThis page intentionally left blank Calibration Factory CalibrationZero Calibration This page intentionally left blank 12.1. M465L Rack Mount Spare Parts List Spare Parts12.2. M465L Nema Spare Parts List Part Number DescriptionCONNECTOR, 16 PIN, W/SCREW Flange This page intentionally left blank Index Permeation Gas Dryer