Furuno SC-50 manual Flush mount S kit Type OP20-17, Code No

Page 24

 

 

 

 

2. INSTALLATION

Flush mount “S”

 

 

 

 

 

Flush mount “S” kit

Type: OP20-17, Code No.: 000-040-720)

 

 

 

 

 

 

Name

 

Type

Code No.

Qty

 

Flush Mount Fixture

 

20-007-2401

100-183-190

2

 

Wing Bolt

 

M4X30

000-804-799

4

 

Wing Nut

 

M4

000-863-306

4

 

Hex Bolt

 

M6X12

000-862-127

2

 

Spring Washer

 

M6

000-864-260

2

 

1.Make a cutout in the mounting location. The dimensions are 167(W) x 92(H) mm.

2.Place the display unit in the cutout.

3.Fix the display unit to the two flush mount fixtures with hex bolts and spring washers.

4.Screw the butterfly nut on the butterfly bolt.

5.Fix the display unit with the butterfly bolt and then tighten the butterfly nut.

Flush mount “S”

2-15

Image 24
Contents Satellite Compass Safety Instructions Table of Contents MAINTENANCE, Troubleshooting IiiFeatures ForewordWord to the Owner of the SC-50 System Configuration System configurationEquipment List Standard supplyOptional equipment Name Type Code No Qty RemarksPrinciple of Operation This page intentionally left blank Installation Mounting ConsiderationsAntenna unit Mast diameter Separation distance minimum Horizontal separation between antenna and mastsAntenna and field of view Example of antenna installed below superstructures Display unit, processor unitInstalling the Antenna Units Mounting dimensions for antenna, orienting the antennaAntenna unit SC-303 Waterproofing the antenna connector How to fasten the antenna cableCoating bolt, nut and washers with silicone sealant Cable from antenna No. marked on cableHow to insert the cable cover Antenna unitHow to orient the antenna elements Antenna unit SC-603Mounting Antenna unit SC-603Fixing antenna unit to pedestal Orient the antenna unit as shown in the illustration below Orienting the antenna unitWelding the antenna unit Fastening the antenna cable Antenna elementInstalling the Processor Unit Deck, bulkhead mountProcessor unit orientation, deck mounting Installation on the underside of a desk Installation of processor unit on the underside of a deskInstalling the Display Unit Desktop, overhead mountingFlush mount Flush mount FFlush mount S Flush mount S kit Type OP20-17, Code NoFlush mount S Wiring General wiring diagramProcessor unit, rear view How to install the optional antenna cable set Sectional view of coaxial cable 3D2VHow to attach connector N-P-8DFB How to attach connector N-P-8DFBInitial Settings Installation setup menuConfirming satellite status choosing mounting method Main menuHeading setup menu Choosing heading sourceSatellite tracking status display General wiring Connection of External EquipmentProcessor unit, cover opened Fabrication of cables Cable Sectional view, fabricationOperation ControlsDisplay unit Turning the Power On/Off Panel Illumination, Display ContrastProcessor unit Choosing a Display Description of displaysHeading display Nav data displaySteering display Compass displayROT Rate-of-Turn display Set and Drift display, Distance Run display Set and drift display, speed and distance run displayDgps Alarm Setup Alarm menuDgps alarm options Buzzer optionsConfirming Satellite Status Satellite status displayGPS Setup Displaying the GPS setup menuGPS Setup menu description Disable SV Disable satellite Output DataHeading Data OUT1 menu, sentences Baud rate optionsTx interval options IEC, Nmea version optionsHeading talker options Log pulse Log pulse optionsSystem Setup System Setup menuGeodetic data Using local time Units of measurementTime format Demonstration mode WAAS/DGPS Setup Position fix mode optionsWAAS/DGPS menu Waas Search optionsProvider GEO Satellite Longitude GEO satellite and coverage areaAUTO/MANUAL options Operation HDG Backup options Others MenuOthers menu HDG Restoration optionsTrip Menu Trip menuResetting Distance Run Reset Distance promptThis page intentionally left blank MAINTENANCE, Troubleshooting Preventive MaintenanceTroubleshooting TroubleshootingSymptom Cause Remedy Diagnostics Diagnostic test1Test menu options Test start promptDiagnostic test sequence Push KEYDiagnostic test2 TEST2 displayDiagnostic test3 Alarm optionsProgram Number Clearing DataProgram version no. display Prompts for erasure of dataReplacement of Battery Battery Location Type Code NoPrompt for exchanging battery Prompt for turning off the powerReplacement of Fuse Error MessagesError Message Meaning Remedy Message displayError messages con’t from previous Data ERRAppendix Menu TreeAP-1 AP-2 Specifications SC-50Furuno Index IN-1Packing List SC-501-J/E SC-303 工事材料表 Installation Materials フラッシュマウントキット 20AY-X-9403 SC-50/55/60 20AT-X-9410 Page Page Page