Furuno SC-50 manual Diagnostic test3, Alarm options

Page 59

4. MAINTENANCE, TROUBLESHOOTING

Diagnostic test3

This test checks the buzzer signal/contact for proper operation.

1.Press the [MENU] key to open the menu.

2.Choose SYS SETUP and then press the [ENT] key.

3.Choose TEST? and then press the [ENT] key.

TEST1

TEST2

TEST3

Test menu options

4. Choose TEST3 and then press the [ENT] key.

TEST START?

(STOP: PWR OFF)

ARE YOU SURE?

YES

NO

Test start prompt

6. Press to choose YES and then press the [ENT] key.

ALARM

ALARM: OFF

ALARM menu

7. Press the [ENT] key.

OFF

ON

ALARM options

8. Choose OFF or ON as appropriate and then press the [ENT] key.

OFF: Buzzer sound goes off, alarm contact signal is closed, and alarm sounds continuously.

ON: The buzzer sounds and the alarm contact is open.

9. To quit the test, turn off the processor unit.

4-6

Image 59
Contents Satellite Compass Safety Instructions Table of Contents Iii MAINTENANCE, TroubleshootingWord to the Owner of the SC-50 FeaturesForeword System configuration System ConfigurationName Type Code No Qty Remarks Equipment ListStandard supply Optional equipmentPrinciple of Operation This page intentionally left blank Antenna unit InstallationMounting Considerations Antenna and field of view Mast diameter Separation distance minimumHorizontal separation between antenna and masts Display unit, processor unit Example of antenna installed below superstructuresAntenna unit SC-303 Installing the Antenna UnitsMounting dimensions for antenna, orienting the antenna Cable from antenna No. marked on cable Waterproofing the antenna connectorHow to fasten the antenna cable Coating bolt, nut and washers with silicone sealantAntenna unit How to insert the cable coverAntenna unit SC-603 How to orient the antenna elementsAntenna unit SC-603 MountingFixing antenna unit to pedestal Orienting the antenna unit Orient the antenna unit as shown in the illustration belowWelding the antenna unit Antenna element Fastening the antenna cableProcessor unit orientation, deck mounting Installing the Processor UnitDeck, bulkhead mount Installation of processor unit on the underside of a desk Installation on the underside of a deskFlush mount F Installing the Display UnitDesktop, overhead mounting Flush mountFlush mount S Flush mount SFlush mount S kit Type OP20-17, Code No Processor unit, rear view WiringGeneral wiring diagram Sectional view of coaxial cable 3D2V How to install the optional antenna cable setHow to attach connector N-P-8DFB How to attach connector N-P-8DFBMain menu Initial SettingsInstallation setup menu Confirming satellite status choosing mounting methodSatellite tracking status display Heading setup menuChoosing heading source Processor unit, cover opened General wiringConnection of External Equipment Cable Sectional view, fabrication Fabrication of cablesDisplay unit OperationControls Processor unit Turning the Power On/OffPanel Illumination, Display Contrast Nav data display Choosing a DisplayDescription of displays Heading displayROT Rate-of-Turn display Steering displayCompass display Set and drift display, speed and distance run display Set and Drift display, Distance Run displayBuzzer options Dgps Alarm SetupAlarm menu Dgps alarm optionsSatellite status display Confirming Satellite StatusGPS Setup menu description GPS SetupDisplaying the GPS setup menu Heading Disable SV Disable satelliteOutput Data Baud rate options Data OUT1 menu, sentencesHeading talker options Tx interval optionsIEC, Nmea version options Log pulse options Log pulseGeodetic data System SetupSystem Setup menu Time format Using local timeUnits of measurement Demonstration mode Waas Search options WAAS/DGPS SetupPosition fix mode options WAAS/DGPS menuAUTO/MANUAL options Provider GEO Satellite LongitudeGEO satellite and coverage area Operation HDG Restoration options HDG Backup optionsOthers Menu Others menuTrip menu Trip MenuReset Distance prompt Resetting Distance RunThis page intentionally left blank Preventive Maintenance MAINTENANCE, TroubleshootingSymptom Cause Remedy TroubleshootingTroubleshooting Test start prompt DiagnosticsDiagnostic test1 Test menu optionsPush KEY Diagnostic test sequenceTEST2 display Diagnostic test2Alarm options Diagnostic test3Prompts for erasure of data Program NumberClearing Data Program version no. displayPrompt for turning off the power Replacement of BatteryBattery Location Type Code No Prompt for exchanging batteryMessage display Replacement of FuseError Messages Error Message Meaning RemedyData ERR Error messages con’t from previousAP-1 AppendixMenu Tree AP-2 SC-50 SpecificationsFuruno IN-1 IndexPacking List SC-501-J/E SC-303 工事材料表 Installation Materials フラッシュマウントキット 20AY-X-9403 SC-50/55/60 20AT-X-9410 Page Page Page