3. OPERATION
3.9System Setup
3.9.1Geodetic data
Your unit is preprogrammed to recognize most of the major chart systems of the world. Although the
1.Press the [MENU] key to open the menu.
2.Choose SYS SETUP and then press the [ENT] key.
SYSTEM SETUP
DATUM | : | WGS84 |
UNITS | : kt | |
TIME DIFF | : +00:00 | |
TIME DISP | : 24 HOUR | |
TEST? |
|
|
DEMO | : OFF |
EXCHANGE BATTERY?
SYSTEM SETUP menu
3.Confirm that the cursor is selecting DATUM and then press the [ENT] key.
4.Choose WGS84 (GPS standard), WGS72 or OTHER according to the nautical chart you use and then press the [ENT] key.
5.If you chose WGS72 or WGS84, press the [DISP] key to finish. For OTHER, go to step 6.
6 Press the [ENT] key.
7.Use the Omnipad to enter chart number, referring to the geodetic chart list on page
8.Press the [ENT] key.
9.Press the [DISP] key to close the menu.