Summit 460-LP, 660-LP manual Ventilation

Page 31

VENTILATION

VENTILATION

m WARNING: Ventilation holes must be provided in the structure at the top and bottom to provide ventilation in the event of a gas leak.

Ventilation holes can be located in a low visibility area and should be protected by screening material to prevent rodents and insects from entering the structure. Air holes will also help dry moisture.

Note: These drawings are only a reference.

• Cross ventilation must be incorporated in the supporting structure. We recommend a minimum of 100 square inches (254 square cm) of venting per side.

• Vents should be on two sides of the structure.

• The drawings are for reference only.

Location of the vents should be from the center, outward.

Locate the vents at both the bottom of the structure and at the top of the structure.

The bottom vents should be as close to ground level as possible. Make sure the vent area is not blocked by interior supports of the structure.

• We recommend vents with screens.

Access doors to the structure are not considered vents.

Clean the vents periodically.

m DANGER

Failure to follow recommended minimum venting instructions can cause gas to collect in the structure in the event of a gas leak. This may result in a fire or an explosion which can cause serious bodily injury or death, and damage to property.

www.weber.com® 31

Image 31
Contents Gas Grill Liquid Propane GAS Units only Island Structure Configuration Options BUILT-IN Cutout DimensionsIsland Structure Configuration Options Locating Your Grill BUILT-IN Structure Cutout DimensionsClearance from Surfaces or Structures General Construction Details BUILT-IN Cutout Detailed DimensionsParts List Lista DE Piezas Liste DES Pieces Tools Needed Herramientas Requeridas Outils Necessaires Assembly Ensamblaje Assemblage460 660 Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage Assembly Ensamblaje Assemblage 460660 Assembly Ensamblaje Assemblage GAS Supply General Specifications for PipingBUILT-IN GAS Line Locations Test Connections Typical 20 LP Propane GAS Supply Installation Operating BUILT-IN Tank Enclosure InstructionsClearance from Combustible Surfaces or Structures Locating Your LP Tank Enclosure KITBUILT-IN Tank Enclosure Parts List / Assembly LP Tank Enclosure GAS Line Locations BUILT-IN Tank Enclosure AssemblyMounting the LP Tank Bracket Mounting the LP Hose and RegulatorGAS Supply Connection Connection ChartConnect GAS Supply Ventilation VentilationMemo Barbacoa de Gas Únicamente Unidades DE GAS Propano Licuado AdvertenciasNota SI Usted HA Comprado UN Quemador Lateral Dimensiones DEL Corte DEL EmpotramientoOpciones DE Configuración DE LAS Estructuras DE LAS Islas Opciones DE Configuración DE LAS Estructuras DE LAS IslasSeparación DE LAS Superficies O Estructuras Dimensiones DEL Corte DE LA Estructura EmpotradaDimensiones Generales DEL Corte DEL Empotrado Ubicación DE LA BarbacoaDetalles Generales DE LA Construcción Dimensiones Detalladas DEL Corte DEL EmpotradoEspecificaciones Generales Para LA Tubería Suministro DE GASUbicaciones DE LAS Líneas DE GAS Empotradas Instalación Típica DE Suministro DE GAS Propano a GranelLongitud de tubería pies Pruebe LAS ConexionesSuministro DE GAS Operación Instrucciones Para EL Compartimiento Empotrado DEL TanqueSeparación DE Superficies O Estructuras Combustibles Ubicación DEL Juego DE Caja Para Tanques DE Propano LicuadoPage Montaje DEL Soporte DEL Tanque DE Propano Licuado Ensamblaje DEL Compartimiento Empotrado DEL TanqueMontaje DEL LA Manguera Y Regulador DEL Propano Licuado Conectar EL Suministro DE GAS Conexión DEL Suministro DE GASCuadro DE Conexiones Ventilación VentilaciónGrill a GAZ Appareils a GAZ Propane Uniquement Mises EN GardeOptions Pour LA Configuration DE LA Structure EN Ilot Dimensions Pour LA Decoupe D’ENCASTRAGERemarque SI Vous Avez Achete UN Bruleur Lateral Zone DE Degagement PAR Rapport AUX Surfaces OU Structures Choisir L’EMPLACEMENT DE Votre GrillDimensions DE Decoupe Pour LA Structure Encastree Dimensions Generales Pour LA Decoupe D’ENCASTRAGEGeneralites SUR LA Construction Dimensions Detaillees Pour LA Decoupe D’ENCASTRAGEArrivee DE GAZ Emplacements DES Conduites DE GAZ EncastreesInstallation D’ARRIVEE DE GAZ Propane EN Vrac Typique Emplacements Pour LA Conduite DE GAZ Integree040 460 050 720 Test DES RaccordsInstallation DE L’ALIMENTATION EN GAZ Propane Utilisation Distance PAR Rapport AUX Surfaces OU Structures Inflammables Localisation DE Votre KIT D’ENTOURAGE DE Bouteille DE PLPage Montage DU Tuyau DE PL ET DU Regulateur Montage DU Support DE LA Bouteille DE PLConnecter L’ARRIVEE DE GAZ Connexion a L’ARRIVEE DE GAZTableau DE Connexion Remarque Ces schémas ne sont fournis qu’à titre de référence Memo Memo Memo WEBER-STEPHEN Products LLC