Vermont Casting RADVTCH, RADVTMB, RADVTSG Assembly Procedures, Tools Required, Parts Bag Contents

Page 14

Radiance Direct Vent Gas Heater

Assembly Procedures

WARNING

Failure to position the parts in accor- dance with these diagrams or failure to

use only parts specifically approved for use with this heater may result in property dam- age or personal injury.

This heater and components are heavy. Have help available for assembly.

Tools Required

Phillips screwdriver (stub)

power drill

utility knife

reciprocating saw

metal drill bit: size 28 (.140”/3.5mm) 9/16” wrench

Parts Bag Contents:

(3) Vent Screws

(2) Switch bracket screws

Wood handle w/insert lifter (handle for operable door)

Restrictor Plate

4” Starter pipe

On-Off switch, housing, and wiring harness

(3)Phillips round-head bolts, 1/4”- 20 x 1/2”

(1) Tube of Vent Gasket Cement

(4) CS, Hex Hd 3/8-16 x 1 Gr 2-Z

(4) Washer, Fl 3/8-Z

Owner Registration Card

Homeowner’s Installation and Operating Manual

Unpack and Assemble Legs

The Radiance is shipped upright. Cut the shipping straps before beginning assembly.

1.Slide stove to the rear of the pallet just far enough to access rear leg holes. Make sure the stove does not tip over backwards. (Fig. 13)

2.Attach the rear legs using 3/8” hex head bolts and flat washer supplied. Tighten with a 9/16” wrench or socket.

3.Carefully tip the stove onto its rear legs. Adjust the pallet to allow access to one of the front leg holes. Be sure to leave the pallet under the stove to pre- vent the stove from falling fully forward. (Fig. 14)

CAUTION: To prevent valve tubing from be- ing crushed or damaged, do not rest valve or ignitor on wooden pallet.

ST720

Fig. 13 Slide stove back just far enough to access rear leg holes.

 

Washer

ST721

Hex Head Bolt

 

Fig. 14 Carefully tip stove onto back legs. Leave pallet under stove to keep stove from falling fully forward.

4.Have your assistant attach one leg using the hard- ware described.

5.Move the pallet to allow access to the other front leg hole. Attach remaining leg.

6.Remove pallet and allow stove to gently rest on all four legs.

7.Adjust leg levelers to compensate for irregularities in the hearth.

NOTE: Verify the two relief doors (located on top of the firebox) are properly seated on the gasket. The doors should sit flush on the gasket, and should lift easily from the seal around the opening.

1414

20012697

Image 14
Contents Radiance Direct Vent Gas Heater Table of Contents Installation & Operating Instructions Commonwealth of MassachusettsRadiance Direct Vent Stove Dimensions Centerline DimensionsClearance Requirements Installation RequirementsLocating The Stove Direct Vent System OnlyWall Centerline from Floor Parallel Installation Minimum Clearance and Flue CenterlineCorner Installation Minimum Clearance and Flue Centerline Wall and Ceiling ClearancesHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal TerminationRestrictor Plate Adjustment Restrictor Plate Adjustment For Extended Pipe RunsRestictor Plate is used on Direct Vent installations only Examples for Extended Run/Restrictor Plate SettingsVent Termination Clearances Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances Minimum Horizontal Vent Kit 2792 Venting Requirements and OptionsApproved Vent System Components Non-adjustable Pipe Twist Lock 48 Straight Pipe CG Non-adjustable Pipe Twist Lock 12 18 Adjustable Pipe12 18 Adjustable Pipe Twist Lock 24 Straight Pipe CG Nonadjustable Pipe Twist Lock 45-Degree Elbow CGTools Required Assembly ProceduresParts Bag Contents Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudFor Canadian installations The venting system must Venting System Assembly General InformationInstall the Vent Adapter Pipe Selkirk Corporation Vent Components Install Vent Adapter PipeSide Wall Termination Assembly Measure the horizontal length Cut the opening Vertical Through the Roof Vent AssemblyVent Termination Below Grade CFM System 9³⁄₈ x 9³⁄₈ 240 x 240 mmSelkirk Direct-Temp Metalbestos Direct Vent System Inlet End Outlet End Vertical VentingHorizontal Venting To TerminationFire Stopping Adjustable Length AJSupporting DIRECT-TEMP Horizontal Support OffsetsBelow grade installation Vertical Installation Fig Install Log Set Minimum Height Above Roof Requirements2626 Connect the Gas Supply Line Burner InformationOperation SIT Pilot Radvt Series Flame & Temperature AdjustmentFlame Characteristics Pilot Radvtc SeriesTo Turn Off Gas To Heater HoneywellTroubleshooting the Gas Control System Radvt Series SIT Nova 820 Millivolt ValveOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On Path Auto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Pilot type 2 Honeywell Pilot Pilot Orifice ConversionPilot Type 1 SIT Pilot Burner Orifice Conversion All ModelsHigh Altitude Orifice Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to LP Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Schematic Diagram Wiring DiagramsOn/Off Switch Wiring Optional ThermostatRadiance Direct Vent Gas Heater Radiance Direct Vent Gas Heater DescriptionFuel Conversion Kits Shell Enamel Parts Radiance Direct Vent Optional Accessories 4848 Radiance Direct Vent Gas Heater 5050 Limited Lifetime Warranty CFM Corporation