Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manu- ally. When lighting the pilot follow these instruc- tions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.Turn the On/Off switch to “OFF” position, set the remote to OFF or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to “OFF”.

 

 

 

ILO

T

�����

���

 

 

 

P

 

t

 

1

 

 

 

 

 

F

 

 

 

lo

 

 

��

��

 

F

 

 

 

P

 

 

 

 

 

i

 

2

O

 

 

 

O

 

 

 

 

 

 

 

F

 

 

 

F

 

 

 

 

 

 

5

 

3

FFO

 

 

 

4

 

 

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety infor- mation above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to “PILOT”.

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.Turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.Turn the On/Off switch to Off position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn clock-

wise to “OFF”. Do not force.

5.Close control access panel.

3030

20012697

Image 30
Contents Radiance Direct Vent Gas Heater Table of Contents Installation & Operating Instructions Commonwealth of MassachusettsRadiance Direct Vent Stove Dimensions Centerline DimensionsClearance Requirements Installation RequirementsLocating The Stove Direct Vent System OnlyWall Centerline from Floor Parallel Installation Minimum Clearance and Flue CenterlineCorner Installation Minimum Clearance and Flue Centerline Wall and Ceiling ClearancesHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal TerminationRestrictor Plate Adjustment Restrictor Plate Adjustment For Extended Pipe RunsRestictor Plate is used on Direct Vent installations only Examples for Extended Run/Restrictor Plate SettingsVent Termination Clearances Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances Venting Requirements and Options Approved Vent System ComponentsMinimum Horizontal Vent Kit 2792 Non-adjustable Pipe Twist Lock 48 Straight Pipe CG Non-adjustable Pipe Twist Lock 12 18 Adjustable Pipe12 18 Adjustable Pipe Twist Lock 24 Straight Pipe CG Nonadjustable Pipe Twist Lock 45-Degree Elbow CGTools Required Assembly ProceduresParts Bag Contents Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudVenting System Assembly General Information Install the Vent Adapter PipeFor Canadian installations The venting system must Install Vent Adapter Pipe Side Wall Termination AssemblySelkirk Corporation Vent Components Measure the horizontal length Cut the opening Vertical Through the Roof Vent AssemblyVent Termination Below Grade CFM System 9³⁄₈ x 9³⁄₈ 240 x 240 mmSelkirk Direct-Temp Metalbestos Direct Vent System Inlet End Outlet End Vertical VentingHorizontal Venting To TerminationFire Stopping Adjustable Length AJSupporting DIRECT-TEMP Horizontal Support OffsetsBelow grade installation Vertical Installation Fig Install Log Set Minimum Height Above Roof Requirements2626 Connect the Gas Supply Line Burner InformationOperation SIT Pilot Radvt Series Flame & Temperature AdjustmentFlame Characteristics Pilot Radvtc SeriesTo Turn Off Gas To Heater HoneywellTroubleshooting the Gas Control System Radvt Series SIT Nova 820 Millivolt ValveOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On Path Auto Path Conversion Precautions Conversion ProcedureFuel Conversion Instructions Pilot Orifice Conversion Pilot Type 1 SIT PilotPilot type 2 Honeywell Pilot Burner Orifice Conversion All ModelsHigh Altitude Orifice Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to LP Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly Schematic Diagram Wiring DiagramsOn/Off Switch Wiring Optional ThermostatRadiance Direct Vent Gas Heater Radiance Direct Vent Gas Heater DescriptionFuel Conversion Kits Shell Enamel Parts Radiance Direct Vent Optional Accessories 4848 Radiance Direct Vent Gas Heater 5050 Limited Lifetime Warranty CFM Corporation