Vermont Casting RADVTCBB Instructions for Comfort Control Valve, Operation, Shut Off Procedure

Page 32

Radiance Direct Vent Gas Heater

Instructions for Comfort Control Valve

RADVTC Series

The Comfort Control valve allows remote control of temperature, fan and flame appearance.

NOTE: The antenna should hang in free air away from grounded metal.

Operation

1.If the manual switch is in remote position, switch it to LOCAL. (Fig. 57)

2.Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner.

3.Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will provide 1 short blink continuously in the normal mode. When the light turns off which will be approxi- mately 10 seconds after it has been continuously red, the receiver/valve is fully powered.

7.If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The transmitter will control the fan only.

Shut Off Procedure

If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. How- ever, the control is still on and a command from the transmitter can turn on the main burner or fan.

To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan.

Transmitter Operation

Off Mode

In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.

Display

Motor Top Cap

Piezo Ignitor

 

 

 

 

PILOT

OFF

 

 

 

 

REMOTE

ON•

 

LOCAL

 

LED

 

 

 

 

 

LED

Local/Remote

Pilotstat

Plug

Switch

Knob

 

 

Mode

Auto

On

Off

Countdown

Timer

Fan

FP1039

Room Temperature

Set Temperature

Flame Height Level

Fan Speed Level

Countdown Timer

Low Battery

Flame

Up

Increases Flame

Height, Fan Speed Timer, or Set Point

Down Decrease Flame, Fan Speed Timer or Set Point

Antenna

Fig. 57 Comfort control valve.

FP1037

Fig. 58 Transmitter diagram.

On (Manual) Mode

4.Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2.

5.Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately.

6.ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the re- ceiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control.

In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.

When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.

Delay Timer Mode

The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes.

3232

20012697

Image 32
Contents Radiance Direct Vent Gas Heater Table of Contents Installation & Operating Instructions Commonwealth of MassachusettsRadiance Direct Vent Stove Dimensions Centerline DimensionsInstallation Requirements Locating The StoveClearance Requirements Direct Vent System OnlyParallel Installation Minimum Clearance and Flue Centerline Corner Installation Minimum Clearance and Flue CenterlineWall Centerline from Floor Wall and Ceiling ClearancesGas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal TerminationRestrictor Plate Adjustment For Extended Pipe Runs Restictor Plate is used on Direct Vent installations onlyRestrictor Plate Adjustment Examples for Extended Run/Restrictor Plate SettingsVent Termination Clearances Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances Minimum Horizontal Vent Kit 2792 Venting Requirements and OptionsApproved Vent System Components Non-adjustable Pipe Twist Lock 12 18 Adjustable Pipe 12 18 Adjustable Pipe Twist Lock 24 Straight Pipe CGNon-adjustable Pipe Twist Lock 48 Straight Pipe CG Nonadjustable Pipe Twist Lock 45-Degree Elbow CGAssembly Procedures Parts Bag ContentsTools Required Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudFor Canadian installations The venting system must Venting System Assembly General InformationInstall the Vent Adapter Pipe Selkirk Corporation Vent Components Install Vent Adapter PipeSide Wall Termination Assembly Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeCut the opening CFM System 9³⁄₈ x 9³⁄₈ 240 x 240 mmSelkirk Direct-Temp Metalbestos Direct Vent System Vertical Venting Horizontal VentingInlet End Outlet End To TerminationAdjustable Length AJ Supporting DIRECT-TEMP Horizontal SupportFire Stopping OffsetsBelow grade installation Vertical Installation Fig Install Log Set Minimum Height Above Roof Requirements2626 Connect the Gas Supply Line Burner InformationOperation Flame & Temperature Adjustment Flame CharacteristicsSIT Pilot Radvt Series Pilot Radvtc SeriesTo Turn Off Gas To Heater HoneywellTroubleshooting the Gas Control System Radvt Series SIT Nova 820 Millivolt ValveShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeAuto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path On Path Auto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Pilot type 2 Honeywell Pilot Pilot Orifice ConversionPilot Type 1 SIT Pilot Burner Orifice Conversion All ModelsAir Shutter Adjustment Injector Orifice Size MatrixHigh Altitude Orifice Conversion to LP Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Wiring Diagrams On/Off Switch WiringSchematic Diagram Optional ThermostatRadiance Direct Vent Gas Heater Radiance Direct Vent Gas Heater DescriptionFuel Conversion Kits Shell Enamel Parts Radiance Direct Vent Optional Accessories 4848 Radiance Direct Vent Gas Heater 5050 Limited Lifetime Warranty CFM Corporation