Vermont Casting RADVTCCH Min. Through the Wall Vent Kit, Starter Kit for Below-Grade Termination

Page 13

Vertical Termination Cap

4DT-VC

CFM Vent Components

The following kits are available to meet the needs of most installations. All pipe has a 7” outer diameter and includes a 4” diameter inner section. A (CG) designa- tion indicates the part is finished in Charcoal Gray paint. Consult your dealer about other vent parts that may be appropriate to complete the installation.

Min. Through the Wall Vent Kit

7TFSSK

(1)

90-Degree Elbow (CG)

 

(1)

24” Straight pipe (CG)

 

(1)

24” - 42” Adjustable Straight Pipe

 

(1)

Side Wall Termination

 

(1)

Firestop

 

(1)

Zero-clearance sleeve

 

(1)

Hardware package

 

(1)

Finishing plate (CG)

 

(1)

Finishing collar (CG)

 

(4)

Charcoal Gray flue pipe rings

 

Starter Kit for Below-Grade Termination

7TDVSKS

(1)

Snorkel Termination (7TDVSNORK)

 

Vertical Termination Kit, 1/12-6/12 Pitch

7TDVSKVA

(1)Combination Horizontal Offset / Roof Support

(1)Vertical Termination

(1)Storm Collar

(1)1/12-6/12 Flashing

(1)Finishing Plate (CG)

(1)Finishing Collar (CG)

(1)Polished Brass Flue Pipe Ring

(1)Hardware Package

Vertical Termination Kit, 7/12-12/12 Pitch

7TDVSKVB

(1)

7/12 - 12/12 Flashing

 

and all of the other Vertical Termination parts.

 

Vertical Termination, Flat Roof

7DVSKVF

(1)

Flat Flashing

 

Radiance Direct Vent Gas Heater

and all of the other Vertical Termination parts.

 

Twist Lock 12” Straight Pipe (CG)

7TFSDVP12

(1)

12” Non-adjustable Pipe

 

Twist Lock 12” - 18” Adjustable Pipe

7TFSDVP1218

(1)

12” - 18” Adjustable Pipe

 

Twist Lock 24” Straight Pipe (CG)

7TFSDVP24

(1)

24” Non-adjustable Pipe

 

Twist Lock 48” Straight Pipe (CG)

7TFSDVP48

(1)

48” Nonadjustable Pipe

 

Twist Lock 45-Degree Elbow (CG)

7TFSDVT45

for vertical offsets

 

(1)

45-degree Elbow

 

Combination Offset/Roof Support

7DVCS

Attic Insulation Shield

7DVAIS

7” Charcoal Gray Pipe Rings, (4)

7FSDRG

7” Polished Brass Pipe Rings (4)

7FSDRP

Wall Thimble

942G

20012697

13

Image 13
Contents Radiance Direct Vent Gas Heater Table of Contents Commonwealth of Massachusetts Installation & Operating InstructionsCenterline Dimensions Radiance Direct Vent Stove DimensionsLocating The Stove Installation RequirementsClearance Requirements Direct Vent System OnlyCorner Installation Minimum Clearance and Flue Centerline Parallel Installation Minimum Clearance and Flue CenterlineWall Centerline from Floor Wall and Ceiling ClearancesGas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal TerminationRestictor Plate is used on Direct Vent installations only Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate Adjustment Examples for Extended Run/Restrictor Plate SettingsLocation of Vent Termination Vent Termination ClearancesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Approved Vent System Components Venting Requirements and OptionsMinimum Horizontal Vent Kit 2792 12 18 Adjustable Pipe Twist Lock 24 Straight Pipe CG Non-adjustable Pipe Twist Lock 12 18 Adjustable PipeNon-adjustable Pipe Twist Lock 48 Straight Pipe CG Nonadjustable Pipe Twist Lock 45-Degree Elbow CGParts Bag Contents Assembly ProceduresTools Required Unpack and Assemble LegsRemove rear shroud Install the Optional FanInstall the Vent Adapter Pipe Venting System Assembly General InformationFor Canadian installations The venting system must Side Wall Termination Assembly Install Vent Adapter PipeSelkirk Corporation Vent Components Measure the horizontal length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyCut the opening CFM System 9³⁄₈ x 9³⁄₈ 240 x 240 mmSelkirk Direct-Temp Metalbestos Direct Vent System Horizontal Venting Vertical VentingInlet End Outlet End To TerminationSupporting DIRECT-TEMP Horizontal Support Adjustable Length AJFire Stopping OffsetsBelow grade installation Vertical Installation Fig Minimum Height Above Roof Requirements Install Log Set2626 Burner Information Connect the Gas Supply LineOperation Flame Characteristics Flame & Temperature AdjustmentSIT Pilot Radvt Series Pilot Radvtc SeriesHoneywell To Turn Off Gas To HeaterSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control System Radvt SeriesTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path On Path Auto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Pilot Type 1 SIT Pilot Pilot Orifice ConversionPilot type 2 Honeywell Pilot All Models Burner Orifice ConversionInjector Orifice Size Matrix Air Shutter AdjustmentHigh Altitude Orifice Conversion to LP Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly On/Off Switch Wiring Wiring DiagramsSchematic Diagram Optional ThermostatRadiance Direct Vent Gas Heater Description Radiance Direct Vent Gas HeaterFuel Conversion Kits Shell Enamel Parts Radiance Direct Vent Optional Accessories 4848 Radiance Direct Vent Gas Heater 5050 Limited Lifetime Warranty CFM Corporation