RADVTVG, RADVTBD, RADVTBB, RADVTC Series: RADVTCG, RADVTGG, RADVTSG, RADVTCCB, RADVTCEB, RADVTCMB, RADVTCBS, RADVTCCH, RADVTCVG, RADVTCBD, RADVTCBB, RADVTCCG, RADVTCSG

Ref.

Description

RADVT/RADVTC

35b.

Pilot Orifice #35 - LP Top Convertible

10002269

36a.

PIlot Orifice PSE RFN

20000908

36b.

PIlot Orifice PSE RFP

20000907

37a.

Orifice Hood 1.75 mm LP

20012946

37b.

Orifice Hood #31 (0.120”) Natural

20006927

37c.

Orifice - High Altitude #33 (0.113”) Natural

20012554

38.

Ignitor Piezo w/ Nut SIT

52464

39.

Bracket Piezo Ignitor (not shown)

20010876

40.

Manifold Assembly

20012202

41.

Air Shutter Assembly

20012204

42.

Trim ON/OFF Switch

30000874

43.

Transmitter Honeywell RF

20002047

44.

Antennae, Honeywell 395783-1

20003561

45.

Wire w/ Straight Term 2 End 50”

10002582

46.

Sensor 2450 CMG-8184-0032

10002013

47.

Gasket Base Pan

20004287

48.

Gasket, HE Door

1203687

49.

Gasket Cement, 3 oz. Tube (not shown)

1206122

50.

Restrictor Plate

20013028

Fuel Conversion Kits

Conversion Kit, NG to LP - RADVTC

Kit 20012900

Conversion Kit, NG to LP - RADVT

Kit 20012729

Conversion Kit, LP to NG - RADVTC

Kit 20012902

Conversion Kit, LP to NG - RADVT

Kit 20012899

High Altitude Conversion Kit

Kit 20013135

20012697

45

Image 45
Contents Radiance Direct Vent Gas Heater Table of Contents Commonwealth of Massachusetts Installation & Operating InstructionsCenterline Dimensions Radiance Direct Vent Stove DimensionsLocating The Stove Installation RequirementsClearance Requirements Direct Vent System OnlyCorner Installation Minimum Clearance and Flue Centerline Parallel Installation Minimum Clearance and Flue CenterlineWall Centerline from Floor Wall and Ceiling ClearancesGas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal TerminationRestictor Plate is used on Direct Vent installations only Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate Adjustment Examples for Extended Run/Restrictor Plate SettingsLocation of Vent Termination Vent Termination ClearancesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements and Options Approved Vent System ComponentsMinimum Horizontal Vent Kit 2792 12 18 Adjustable Pipe Twist Lock 24 Straight Pipe CG Non-adjustable Pipe Twist Lock 12 18 Adjustable PipeNon-adjustable Pipe Twist Lock 48 Straight Pipe CG Nonadjustable Pipe Twist Lock 45-Degree Elbow CGParts Bag Contents Assembly ProceduresTools Required Unpack and Assemble LegsRemove rear shroud Install the Optional FanVenting System Assembly General Information Install the Vent Adapter PipeFor Canadian installations The venting system must Install Vent Adapter Pipe Side Wall Termination AssemblySelkirk Corporation Vent Components Measure the horizontal length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyCut the opening CFM System 9³⁄₈ x 9³⁄₈ 240 x 240 mmSelkirk Direct-Temp Metalbestos Direct Vent System Horizontal Venting Vertical VentingInlet End Outlet End To TerminationSupporting DIRECT-TEMP Horizontal Support Adjustable Length AJFire Stopping OffsetsBelow grade installation Vertical Installation Fig Minimum Height Above Roof Requirements Install Log Set2626 Burner Information Connect the Gas Supply LineOperation Flame Characteristics Flame & Temperature AdjustmentSIT Pilot Radvt Series Pilot Radvtc SeriesHoneywell To Turn Off Gas To HeaterSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control System Radvt SeriesTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path On Path Auto Path Conversion Precautions Conversion ProcedureFuel Conversion Instructions Pilot Orifice Conversion Pilot Type 1 SIT PilotPilot type 2 Honeywell Pilot All Models Burner Orifice ConversionInjector Orifice Size Matrix Air Shutter AdjustmentHigh Altitude Orifice Conversion to LP Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly On/Off Switch Wiring Wiring DiagramsSchematic Diagram Optional ThermostatRadiance Direct Vent Gas Heater Description Radiance Direct Vent Gas HeaterFuel Conversion Kits Shell Enamel Parts Radiance Direct Vent Optional Accessories 4848 Radiance Direct Vent Gas Heater 5050 Limited Lifetime Warranty CFM Corporation