Radiance Direct Vent Gas Heater
Parallel Installation:
Minimum Clearance and Flue Centerline
42" (1070mm)
Min. Alcove Width
4" (102mm)
48"
(1220mm) Max. Alcove Depth
|
|
| 6" |
|
|
| 6" |
|
|
|
|
|
|
| |||||
ST130 |
| (150mm) |
|
|
| (150mm) | |||
|
|
|
|
|
|
|
|
|
Fig. 3 Parallel installation, minimum back and side clear- ances, and flue centerlines.
Corner Installation:
Minimum Clearance and Flue Centerline
18"
(457mm)
6"
�(150mm)
�
18"
(457mm)
�
�
6"
(150mm)
ST129
Fig. 4 Corner installation, minimum corner clearances and flue centerline.
Wall Centerline from Floor
Direct Vent Only
A
ST131b
A
Effective Minimum
Centerline 57” (1448 mm) (CFM Corporation Pipe) 55” (1399 mm) (Simpson DuraVent Pipe)
Fig. 5 Minimum wall centerline.
Wall and Ceiling Clearances
Direct Vent Only |
|
|
|
| D |
|
|
|
| ||
|
|
|
|
|
|
B
C
A
A: Rear Wall | 4” (102 mm) | |
B: Min. Clearance | 44” (1118 mm)* | |
C: Min. Alcove Height | 72” | (1830 mm)* |
D: Max. Alcove Depth | 48” | (1220 mm) |
Sidewall Clearance | 6” (150 mm) |
*needed for installing DuraVent Minimum Vent Kit #2792 or
CFM Corporation Minimum Vent Kit #7TFSMSK. | ST101b |
|
Fig. 6 Dimensions and clearances to ceiling or alcove.
Hearth Requirements
The Radiance Heater must be installed on rigid flooring. When the heater is installed directly on any combustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth require- ments.