Vermont Casting RADVTCSG, RADVTMB, RADVTSG Troubleshooting the Gas Control System Radvt Series

Page 31

Radiance Direct Vent Gas Heater

Troubleshooting the Gas Control System (RADVT Series)

SIT NOVA 820 MILLIVOLT VALVE

NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position.

 

Symptom

Possible Causes

Corrective Action

 

 

 

 

1.

Spark ignitor will not light

A. Defective or misaligned electrode

Using a match, light pilot. If pilot lights, turn off pilot and

 

 

at pilot

push the red button again. If pilot will not light - check

 

 

 

gap at electrode and pilot-should be 1/8” to have a

 

 

 

strong spark.

 

 

 

 

 

 

B. Defective ignitor (Push Button)

With the control knob in the pilot position, push the

 

 

control knob all the way and hold. Check for spark at

 

 

 

 

 

 

electrode and pilot. If no spark to pilot, and electrode

 

 

 

wire is properly connected, replace the battery in the

 

 

 

ignitor module and try again. Refer to Maintenance

 

 

 

Section. If the problem still exists, replace the ignitor

 

 

 

module box.

 

 

 

 

2.

Pilot will not stay lit after

A. Defective pilot generator (thermo-

Check pilot flame. Must impinge on thermocouple/ther-

mopile. NOTE: This pilot burner assembly utilizes both

 

carefully following lighting

couple), remote wall switch

 

a thermocouple and a thermopile. The thermocouple

 

instructions

 

 

 

operates the main valve operation (On and Off). Clean

 

 

 

 

 

 

and or adjust pilot for maximum flame impingement on

 

 

 

thermopile and thermocouple.

 

 

 

 

 

 

B. Defective automatic valve

Turn valve knob to “Pilot”. Maintain flow to pilot; millivolt

 

 

 

meter should read greater than 10mV. If the reading

 

 

 

is okay and the pilot does not stay on, replace the gas

 

 

 

valve. NOTE: An interrupter block (not supplied) must

 

 

 

be used to conduct this test.

 

 

 

 

3.

Pilot burning, no gas to

A. Wall switch or wires defective

Check wall switch and wires for proper connections.

Jumper wire across terminals at wall switch, if burner

 

main burner

 

 

 

comes on, replace defective wall switch.. If okay,

 

 

 

 

 

 

jumper wires across wall switch wires at valve, if burner

 

 

 

comes on, wires are faulty or connections are bad.

 

 

 

 

 

 

B. Thermopile may not be generat-

1. Be sure wire connections form thermopile at gas

 

 

valve terminals are tight and thermopile is fully

 

 

ing sufficient millivoltage

 

 

inserted into pilot bracket.

 

 

 

 

 

 

2. One of the wall switch wires may be grounded. Re-

 

 

 

move wall switch wires form valve terminals if pilot

 

 

 

now stays lit, trace wall switch wiring for ground.

 

 

 

May be grounded to fireplace or gas supply.

 

 

 

3. Check thermopile with millivolt meter. Take reading

 

 

 

at thermopile terminals of gas valve. Should read

 

 

 

250-300 millivolts (minimum 150) while holding

 

 

 

valve knob depressed in pilot position and wall

 

 

 

switch “Off”. Replace faulty thermopile if reading is

 

 

 

below specified minimum.

 

 

 

 

 

 

C. Plugged burner orifice

Check burner orifices for debris and remove.

 

 

 

 

 

 

D. Defective automatic valve opera-

Turn valve knob to “On”, place wall switch to “On”

 

 

millivolt meter should read greater than 150mV. If the

 

 

tor

 

 

reading is okay and the burner does not come on,

 

 

 

 

 

 

replace the gas valve.

 

 

 

 

4.

Frequent pilot outage

A. Pilot flame may be too low or

Clean and/or adjust pilot flame for maximum flame

impingement on thermopile and thermocouple.

 

problem

blowing (high) causing the pilot

 

 

 

 

safety to drop out

 

 

 

 

 

 

 

B. Possible blockage of the vent

Check the vent terminal for blockage (recycling the flue

 

 

terminal

gases).

 

 

 

 

20012697

31

Image 31
Contents Radiance Direct Vent Gas Heater Table of Contents Commonwealth of Massachusetts Installation & Operating InstructionsCenterline Dimensions Radiance Direct Vent Stove DimensionsDirect Vent System Only Installation RequirementsLocating The Stove Clearance RequirementsWall and Ceiling Clearances Parallel Installation Minimum Clearance and Flue CenterlineCorner Installation Minimum Clearance and Flue Centerline Wall Centerline from FloorHorizontal Termination Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsExamples for Extended Run/Restrictor Plate Settings Restrictor Plate Adjustment For Extended Pipe RunsRestictor Plate is used on Direct Vent installations only Restrictor Plate AdjustmentLocation of Vent Termination Vent Termination ClearancesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Approved Vent System Components Venting Requirements and OptionsMinimum Horizontal Vent Kit 2792 Nonadjustable Pipe Twist Lock 45-Degree Elbow CG Non-adjustable Pipe Twist Lock 12 18 Adjustable Pipe12 18 Adjustable Pipe Twist Lock 24 Straight Pipe CG Non-adjustable Pipe Twist Lock 48 Straight Pipe CGUnpack and Assemble Legs Assembly ProceduresParts Bag Contents Tools RequiredRemove rear shroud Install the Optional FanInstall the Vent Adapter Pipe Venting System Assembly General InformationFor Canadian installations The venting system must Side Wall Termination Assembly Install Vent Adapter PipeSelkirk Corporation Vent Components Measure the horizontal length CFM System 9³⁄₈ x 9³⁄₈ 240 x 240 mm Vertical Through the Roof Vent AssemblyVent Termination Below Grade Cut the openingSelkirk Direct-Temp Metalbestos Direct Vent System To Termination Vertical VentingHorizontal Venting Inlet End Outlet EndOffsets Adjustable Length AJSupporting DIRECT-TEMP Horizontal Support Fire StoppingBelow grade installation Vertical Installation Fig Minimum Height Above Roof Requirements Install Log Set2626 Burner Information Connect the Gas Supply LineOperation Pilot Radvtc Series Flame & Temperature AdjustmentFlame Characteristics SIT Pilot Radvt SeriesHoneywell To Turn Off Gas To HeaterSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control System Radvt SeriesDelay Timer Mode Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeDisable Thermostat Function Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLocal Path On Path Auto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Pilot Type 1 SIT Pilot Pilot Orifice ConversionPilot type 2 Honeywell Pilot All Models Burner Orifice ConversionConversion to LP Input BTU/h Air Shutter AdjustmentInjector Orifice Size Matrix High Altitude OrificeMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly Optional Thermostat Wiring DiagramsOn/Off Switch Wiring Schematic DiagramRadiance Direct Vent Gas Heater Description Radiance Direct Vent Gas HeaterFuel Conversion Kits Shell Enamel Parts Radiance Direct Vent Optional Accessories 4848 Radiance Direct Vent Gas Heater 5050 Limited Lifetime Warranty CFM Corporation