2.Install the rear log by plac- ing it on the ember bed toward the back of the firebox. (Fig. 48) The log should touch the back wall of the firebox. When the log is in place, the two (2) notches on the bottom of the log rest on the two (2) ribs on the back side of the ember bed. (Fig. 49)

Rear Log

Figure 48

LG488

Ribs for Rear Log

Figure 49

Ember Bed

 

LG487

Rib and Flat Spot

Rib Flat Spot forfor Front Right Log

Front Left Log

3.Install the front left and right logs (Fig. 50) by placing them on the ribs shown in Figure 49. Make sure the logs line up with the flat spots on the ember bed intended for location purposes. (Fig. 49)

4.Install the left cross log by engag- ing the hole on the bottom with the pin on the left side of the rear log. Set front side of cross log on notch in ember bed. (Fig. 51)

5.Install the right cross log by engaging the hole on the bottom with the pin on the right side of the rear log. Set front edge of cross log on ember bed as shown in Figure 51.

Figure 50

LG489

Front Right Log

Front Left Log

2626

20012697

Image 26
Contents Radiance Direct Vent Gas Heater Table of Contents Installation & Operating Instructions Commonwealth of MassachusettsRadiance Direct Vent Stove Dimensions Centerline DimensionsClearance Requirements Installation RequirementsLocating The Stove Direct Vent System OnlyWall Centerline from Floor Parallel Installation Minimum Clearance and Flue CenterlineCorner Installation Minimum Clearance and Flue Centerline Wall and Ceiling ClearancesHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal TerminationRestrictor Plate Adjustment Restrictor Plate Adjustment For Extended Pipe RunsRestictor Plate is used on Direct Vent installations only Examples for Extended Run/Restrictor Plate SettingsVent Termination Clearances Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances Minimum Horizontal Vent Kit 2792 Venting Requirements and OptionsApproved Vent System Components Non-adjustable Pipe Twist Lock 48 Straight Pipe CG Non-adjustable Pipe Twist Lock 12 18 Adjustable Pipe12 18 Adjustable Pipe Twist Lock 24 Straight Pipe CG Nonadjustable Pipe Twist Lock 45-Degree Elbow CGTools Required Assembly ProceduresParts Bag Contents Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudFor Canadian installations The venting system must Venting System Assembly General InformationInstall the Vent Adapter Pipe Selkirk Corporation Vent Components Install Vent Adapter PipeSide Wall Termination Assembly Measure the horizontal length Cut the opening Vertical Through the Roof Vent AssemblyVent Termination Below Grade CFM System 9³⁄₈ x 9³⁄₈ 240 x 240 mmSelkirk Direct-Temp Metalbestos Direct Vent System Inlet End Outlet End Vertical VentingHorizontal Venting To TerminationFire Stopping Adjustable Length AJSupporting DIRECT-TEMP Horizontal Support OffsetsBelow grade installation Vertical Installation Fig Install Log Set Minimum Height Above Roof Requirements2626 Connect the Gas Supply Line Burner InformationOperation SIT Pilot Radvt Series Flame & Temperature AdjustmentFlame Characteristics Pilot Radvtc SeriesTo Turn Off Gas To Heater HoneywellTroubleshooting the Gas Control System Radvt Series SIT Nova 820 Millivolt ValveOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On Path Auto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Pilot type 2 Honeywell Pilot Pilot Orifice ConversionPilot Type 1 SIT Pilot Burner Orifice Conversion All ModelsHigh Altitude Orifice Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to LP Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Schematic Diagram Wiring DiagramsOn/Off Switch Wiring Optional ThermostatRadiance Direct Vent Gas Heater Radiance Direct Vent Gas Heater DescriptionFuel Conversion Kits Shell Enamel Parts Radiance Direct Vent Optional Accessories 4848 Radiance Direct Vent Gas Heater 5050 Limited Lifetime Warranty CFM Corporation