Radiance Direct Vent Gas Heater
5.Replace glass and stove front.
6.Restore gas to system and relight appliance accord- ing to Lighting Instructions on Page 30.
7.Leak check the system using a gas leak detector solution.
8.Relight the main burner in both the “HI” and “LO” po- sitions to verify proper burner ignition and operation.
Conversion is complete.
Table 2. Injector Orifice Size Matrix
Conversion to LP
|
|
|
|
|
|
|
| Input (BTU/h) | ||
| Model |
| Kit # |
| Orifice |
| Part # | Minimum |
| Maximum |
| RADVT |
| 20012729 |
| 1.75 mm |
| 20012946 | 25,000 |
| 36,000 |
|
|
|
|
|
|
| ||||
| RADVTC |
| 20012900 |
| ||||||
|
|
|
|
|
|
|
|
| ||
|
|
| Conversion to Natural Gas |
|
|
| ||||
|
|
|
|
|
|
|
| Input (BTU/h) | ||
| Model |
| Kit # | Orifice | Part # | Minimum | Maximum | |||
| RADVT | 20012899 |
| #31 / 0.120” | 20006927 | 25,000 |
| 38,000 | ||
| RADVTC | 20012902 |
|
| ||||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
Table 3. Air Shutter Adjustment
| Natural Gas | Natural Gas | LP |
Model |
| High Altitude |
|
RADVT/RADVC | 1/2” Open | 1/2” Open | 1/2” Open |
Table 4. High Altitude Orifice
[Required for altitudes above 2000’ (610 m) up to 4500’ (1,370 m)]
|
|
| Input (BTU/h) | |
Model | Orifice | Part # | Minimum | Maximum |
RADVT/RADVTC | #33 / 0.113” | 20012554 | 25,000 | 36,000 |
(Natural gas only) |
|
|
|
|
*LP models do not need
20012697 | 39 |