Vermont Casting RADVTCBS, RADVTMB, RADVTSG, RADVTCG, RADVTEB, RADVTCBD, RADVTGG Optional Accessories

Page 47

Radiance Direct Vent Gas Heater

Optional Accessories

Fan Kits

FK26 Fan

The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture. A rheostat provides for variable fan speeds.

Specifications

115 Volt / 60Hz / .75 Amps

Maintenance

The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surround- ing area is required.

Installation

Refer to Page 15 for installation instructions.

Remote Controls

The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 43 for wiring diagrams. These remote controls are for use with RN/RP models.

Model

Functions Controlled

RC1

ON/OFF

RC2

ON/OFF and Temperature

IMTFK

Wall mounted thermostat control

Screen Kit

An optional screen, R40SK, for use with the operable doors is available to allow the doors to be left in the open position.

Warming Shelf

Warming shelves add versatility to your stove; they can be used to keep foods warm at mealtime.

Model

Color

1560

Classic Black

1555

Biscuit

1556

Chestnut Brown

1557

Ebony

1558

Vermont Classic Green

1562

Sand

1565

Bordeaux

1566

Forest Green

1567

Midnight Blue

1568

Suede Brown

30220

Brick Blue

30222

Country Cookware Gray

30223

Granite Gray

30224

Sage Green

The shelf installation is done in three stages. First you attach the shelf loosely to the stove, leaving the screws loose enough to allow final adjustments. Then, you po- sition the shelf and adjust the brackets so the shelf fits correctly. Finally, you tighten the screws.

Refer to the instructions included with each warming shelf for complete installation procedures.

Decorative Rings

7” brass or charcoal gray rings are available to add a decorative touch to the exposed stove pipe.

Model

Description

7FSDRG/4

7” Charcoal Gray Rings (4)

7FSDRP/4

7” Polished Brass Rings (4)

20012697

47

Image 47
Contents Radiance Direct Vent Gas Heater Table of Contents Commonwealth of Massachusetts Installation & Operating InstructionsCenterline Dimensions Radiance Direct Vent Stove DimensionsDirect Vent System Only Installation RequirementsLocating The Stove Clearance RequirementsWall and Ceiling Clearances Parallel Installation Minimum Clearance and Flue CenterlineCorner Installation Minimum Clearance and Flue Centerline Wall Centerline from FloorHorizontal Termination Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsExamples for Extended Run/Restrictor Plate Settings Restrictor Plate Adjustment For Extended Pipe RunsRestictor Plate is used on Direct Vent installations only Restrictor Plate AdjustmentLocation of Vent Termination Vent Termination ClearancesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Minimum Horizontal Vent Kit 2792 Venting Requirements and OptionsApproved Vent System Components Nonadjustable Pipe Twist Lock 45-Degree Elbow CG Non-adjustable Pipe Twist Lock 12 18 Adjustable Pipe12 18 Adjustable Pipe Twist Lock 24 Straight Pipe CG Non-adjustable Pipe Twist Lock 48 Straight Pipe CGUnpack and Assemble Legs Assembly ProceduresParts Bag Contents Tools RequiredRemove rear shroud Install the Optional FanFor Canadian installations The venting system must Venting System Assembly General InformationInstall the Vent Adapter Pipe Selkirk Corporation Vent Components Install Vent Adapter PipeSide Wall Termination Assembly Measure the horizontal length CFM System 9³⁄₈ x 9³⁄₈ 240 x 240 mm Vertical Through the Roof Vent AssemblyVent Termination Below Grade Cut the openingSelkirk Direct-Temp Metalbestos Direct Vent System To Termination Vertical VentingHorizontal Venting Inlet End Outlet EndOffsets Adjustable Length AJSupporting DIRECT-TEMP Horizontal Support Fire StoppingBelow grade installation Vertical Installation Fig Minimum Height Above Roof Requirements Install Log Set2626 Burner Information Connect the Gas Supply LineOperation Pilot Radvtc Series Flame & Temperature AdjustmentFlame Characteristics SIT Pilot Radvt SeriesHoneywell To Turn Off Gas To HeaterSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control System Radvt SeriesDelay Timer Mode Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeDisable Thermostat Function Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLocal Path On Path Auto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Pilot type 2 Honeywell Pilot Pilot Orifice ConversionPilot Type 1 SIT Pilot All Models Burner Orifice ConversionConversion to LP Input BTU/h Air Shutter AdjustmentInjector Orifice Size Matrix High Altitude OrificeMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Optional Thermostat Wiring DiagramsOn/Off Switch Wiring Schematic DiagramRadiance Direct Vent Gas Heater Description Radiance Direct Vent Gas HeaterFuel Conversion Kits Shell Enamel Parts Radiance Direct Vent Optional Accessories 4848 Radiance Direct Vent Gas Heater 5050 Limited Lifetime Warranty CFM Corporation