GENERAL INSTRUCTIONS

Your Weber® gas barbecue is a portable outdoor cooking appliance.. With the Weber® gas barbecue you can grill, barbecue, roast and bake with results that are difficult to duplicate with indoor kitchen appliances.. The closed lid and Flavorizer® bars produce that “outdoor” flavor in the food..

The Weber® gas barbecue is portable so you can easily change its location in your yard or on your patio.. Portability means you can take your Weber® gas barbecue with you if you move..

The natural gas supply is easy to use and gives you more cooking control than charcoal fuel..

These instructions will give you the minimum requirements for assembling your Weber® gas barbecue.. Please read the instructions carefully before using your Weber® gas barbecue.. Improper assembly can be dangerous..

Not for use by children..

If there are local codes that apply to portable gas grills, you will have to conform to them.. Installation must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223..1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149..1, or Propane Storage and Handling Code, B149..2, or the Standard for Recreational Vehicles, ANSI A 119..2/NFPA 1192, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable..

This Weber® gas barbecue is designed for natural (piped in city) gas only.. Do not use liquid propane (LP) bottled gas.. The valves, orifices and hose are for natural gas only..

Do not use with charcoal fuel..

Check that the area under the control panel and the grease tray are free from debris that might obstruct the flow of combustion or ventilation air..

CANADIAN INSTALLATION

These instructions, while generally acceptable, do not necessarily comply with the Canadian Installation codes, particularly with piping above and below ground.. In Canada the installation of this appliance must comply with local codes and/or Standards CAN/ CGA-B149..1 (Installation Code for Natural Gas Burning Appliances and Equipment)..

STORAGE AND/OR NONUSE

The gas must be turned off at the natural gas supply when the Weber® gas barbecue is not in use..

When the Weber® gas barbecue is stored indoors, the gas supply must be disconnected..

The Weber® gas barbecue should be checked for gas leaks and any obstructions in the burner tubes before using.. (Refer to: “MAINTENANCE/ANNUAL MAINTENANCE”)..

Check that the areas under the control panel and the slide out grease tray are free from debris that might obstruct the flow of combustion or ventilation air..

The Spider/Insect screens should also be checked for any obstructions.. (Refer to: “MAINTENANCE/ANNUAL MAINTENANCE”)..

OPERATING

mWARNING: Only use this barbecue outdoors in a well- ventilated area. Do not use in a garage, building, breezeway or any other enclosed area.

mWARNING: Your Weber® gas barbecue shall not be used under overhead combustible construction.

mWARNING: Your Weber® gas barbecue is not intended to be installed in or on recreational vehicles and/or boats.

mWARNING: Do not use the barbecue within 24 inches of combustible materials. This includes the top, bottom, back or sides of the grill.

mWARNING: The entire cookbox gets hot when in use. Do not leave unattended.

mWARNING: Keep any electrical supply cord and the fuel supply hose away from any heated surface.

mWARNING: Keep the cooking area clear of flammable vapors and liquids, such as gasoline, alcohol, etc., and combustible materials.

GAS SUPPLY TESTING

Disconnect your Weber® gas barbecue when the gas supply is being tested at high pressures.. This appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3..5 kPa)..

Turn off your Weber® gas barbecue when the gas supply is being tested at low pressures.. This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at the pressure equal to or less than 1/2 psig (3..5 kPa)..

WWW.WEBER.COM® 7

Image 7
Contents GAS Grill Liquid Propane GAS Units only Table of Contents VEXPLODED View 310 Diagrama DE Despiece 310 VUE Eclatee Locking Caster Wire Clips Grapas de alambreThermometer Bezel Shroud Cubierta Etui Handle Asa Poignée Warming RackWarranty Storage AND/OR Nonuse Canadian InstallationOperating GAS Supply Testing General InstructionsGas Line Piping Install GAS SupplyGeneral Specifications For Piping GAS Instructions ModelNatural GAS Connection What is Natural GAS?GAS Instructions Type of GASCheck for GAS Leaks Remove Control Knobs & Control Panel For Leak TestingCheck Reinstall Control PanelHose Inspection Before Using the GrillSlide OUT Grease Tray and Disposable Drip PAN Electronic Igniter InspectionElectronic Ignition System Main Burner Ignition & UsageMain Burner Ignition To ExtinguishMain Burner Manual Ignition Drippings and Grease Grilling Tips & Helpful HintsFlavorizer System Preheating Covered CookingProblem Check Solution TroubleshootingCleaning MaintenanceWeber SPIDER/INSECT Screens Control Panel Removal Burner Tubes Cleaning or ReplacementBurner Tube Reinstallation Burner Tube CleaningBurner Tube Removal Electronic Ignition System Operations Igniter Module Wire Guide 310/320Inspection And Cleaning Of The Spider/Insect Screens Annual MaintenanceBurner Flame Pattern WEBER-STEPHEN Products CO Barbacoa DE GAS Únicamente Unidades DE GAS Propano Licuado AdvertenciasInstrucciones Sobre EL GAS Model 310 Tabla DE ContenidoGarantía Instrucciones Generales Tubería de la línea de gas Instrucciones Sobre EL GAS ModelInstale EL Suministro DE GAS Especificaciones generales para la tuberíaConexión DEL GAS Natural Instrucciones Sobre EL GASTipo DE GAS ¿QUÉ ES EL GAS NATURAL?Detección DE Fugas DE GAS Reinstale el panel de control VerificarInspección DEL Encendedor Electrónico Antes DE Utilizar LA BarbacoaInspección DE LA Manguera Sistema de encendido electrónico Encendido Y USO DEL Quemador PrincipalEncendido DEL Quemador Principal Para ApagarEncendido Manual DEL Quemador Principal EL Sistema Flavorizer Consejos Prácticos Para AsarCocción Cubierta Pringues Y GrasaProblema Verifique Solución Resolución DE ProblemasLimpieza MantenimientoMallas Weber Contra Arañas E Insectos Retiro del panel de control Limpieza O Reemplazo DE LOS Tubos QuemadoresLimpieza de los tubos quemadores Retiro del tubo quemadorReinstalación del tubo quemador Guía DE Cableado DEL Módulo DE Encendido 310/320 Operaciones DEL Sistema DE Encendido ElectrónicoPatrón de la llama del quemador Mantenimiento AnualImpreso en los EE.UU Grill a GAZ Appareils a GAZ Propane Uniquement Mises EN GardeInstructions Relatives AU GAZ Model 310 Table DES MatieresGarantie Utilisation Installation AU CanadaGeneralites StockageCanalisation de la conduite de gaz Installer L’ARRIVEE DE GAZInstructions Relatives AU GAZ Model Spécifications générales de la canalisationRaccordement AU GAZ Naturel Instructions Relatives AU GAZType DE GAZ QU’EST-CE QUE LE GAZ Naturel ?Detection DES Fuites DE GAZ Vérifiez Réinstaller le panneau de commandeInspection DU Tuyau Avant D’UTILISER LE GrillPLATEAU-EGOUTTOIR Amovible ET Egouttoir Jetable Inspection DE L’ALLUMEUR ElectroniqueSystème d’allumage électronique Allumage ET Utilisation DU Bruleur PrincipalAllumage DU Bruleur Principal Pour EteindreAllumage Manuel DU Bruleur Principal Système Flavorizer Conseils & Astuces Pour LES GrilladesCuisson Couverte Ecoulements DE JUS ET DE GraissesDepannage Probleme Verification SolutionGrilles ANTI-ARAIGNEES/INSECTES Weber NettoyageRetrait du panneau de commande Nettoyage OU Remplacement DES Tubes DU BruleurRetrait du tube du brûleur Réinstallation du tube du brûleurNettoyage du tube du brûleur Guide DE Cablage DU Module DE L’ALLUMEUR 310/320 Utilisation DU Systeme D’ALLUMAGE ElectroniqueAspect des flammes du brûleur Maintenance AnnuelleMemo Memo Imprimé aux U.S.A