Omron NE-U22V How to Care for Unit After Use, Be sure to wash and store the unit after use

Page 9
(Refer to Page 18)

How to Care for Unit After Use

Be sure to wash and store the unit after use.

If you do not wash the unit after inhalation, the medication will dry and adhere, and may not be nebulized. In that case, disinfect Mesh Cap and wash off dried medication.

1Remove the parts from the Main Unit.

Use

 

Remove the Child’s Inhalation Mask or Mouthpiece, Mask Adapter, and Medication Bottle

 

from the Main Unit. (For how to assemble the Main Unit, refer to Page 8 to 9)

After

 

2 Discard the remaining medication.

 

Unit

 

 

Disengage the

Discard the

 

 

for

 

Medication Bottle

 

Cap Locking

remaining

Care

 

Lever and open

medication.

 

the Medication

 

 

 

 

How to

 

Bottle Cap.

 

 

 

 

Unut

3

Wash the parts.

 

the

 

 

Wash the Inhalation Mask or Mouthpiece, Mask Adapter,

 

of

 

 

 

and Medication Bottle in the water.

 

Use

 

 

 

General Advice

 

Correct

 

 

 

Do not wash Medication Bottle and Mesh Cap under strong

 

 

running tap water.

• It may cause damage.

4Dry parts thoroughly.

Immediately after washing the parts, wipe off excess water with a dry cloth, and allow to air dry.

Remove the Mesh Cap from the Medication Bottle and air dry. (Refer to Page 8)

– Do not touch the Mesh with your hand.

How to Care for Unit After Use

5 After assembling the unit, store it in a clean environment.

Warning

Wash and disinfect Medication Bottle, Inhalation Mask, Mouthpiece, and Mask Adapter after each use. (Refer to Page 16)

Be sure to dry the cleaned and disinfected parts promptly, and store them without getting re-contamination.

When the main unit is dirty

 

 

Correct

Wipe the stain on the Main Unit with a soft cloth. If the Main Unit is heavily stained, wipe it with

 

a soft cloth moistened with water or detergent and squeezed well. Then wipe it with a dry soft cloth.

Use

General Advice

of

• Do not clean the Main Unit with volatile chemical such as benzene or thinner.

the

• Do not immerse the Main Unit in Water.

 

Unit

How to Carry the Unit

How

• You can put Mouthpiece and Inhalation Mask in the storage case to carry them with the unit.

• Put a Main Unit Cover over the Main Unit when carrying the unit.

to

• Do not put the AC Adapter in the storage case along with the Main Unit.

Care for

The Main Unit may be scratched.

Bundle the power cord of the AC Adapter and fasten it to the Main Unit of the

Unit After Use

AC Adapter with the cord band.

 

Cord band

 

General Advice

 

Do not leave or carry the Medication Bottle filled with medication or water.

The medication may drip or spill and damage the Main Unit. Do not store the unit under high temperature, high humidity, or in direct sunlight.

16

17

Image 9
Contents How to Disinfect the Unit Before Using the UnitTroubleshooting and Warranty Model NE-U22VSafety Information Safety InformationPocket-sized unit can be easily carried anywhere you go Features of the ProductInhalation is possible at various angles Simple care and easy useNames and Functions of the Parts Components of the Product Please check the productThis unit must be assembled before it is used How to Assemble the Main UnitAttach the Mesh Cap on the Medication Bottle Now you have completed assembling the Main UnitHow to Insert Batteries How to Use the Power SourceHow to Use optional AC Adapter optional How to remove the AC Adapter from the Main UnitAttach the Mouthpiece, Mask Adapter How to Fill the Medication BottleFill Medication Bottle Close the mesh capHow to Inhale How to Select the Nebulization ModeHow to Carry the Unit How to Care for Unit After UseWhen the main unit is dirty Be sure to wash and store the unit after useHow to Disinfect How to Replace the Mesh CapFollowing parts can be disinfected Troubleshooting TroubleshootingWhere to Inspect How to correct TroubleshootingWarranty SpecificationsSpecifications Replacement Parts and AccessoriesAvant d’utiliser l’appareil Distributed byUtilisation de l’appareil Désinfection de l’appareilConseils de sécurité Conseils de sécuritéIndicateur de Signification Peut se produire à la suite d’une manipulation incorrecteInhalation possible à divers angles Caractéristiques du produitEntretien et utilisation faciles SécuritéDescription des pièces Composants du produitLes items suivants sont contenus dans la boîte Omron le plus prèsCet appareil doit être assemblé avant d’être utilisé Assemblage de l’appareil principalUtilisation de la source d’énergie Installation des pilesUtilisation facultative de l’adaptateur CA en option Enlevez le couvercle de pileComment remplir bouteille de médicament Fixez l’embout buccal et l’adaptateur de masqueFixez la masque d’inhalation pour enfant ou l’embout buccal Nébulisation en mode continu Sélection du mode de nébulisationNébulisation en mode manuel InhalationEntretien après utilisation Transport de l’appareilSi l’appareil principal est sale Désinfection Replacement de la capsule-filtreDépannage DépannageRecherchez Corrigez DépannagePièces de remplacement et accessoires SpécificationsGarantie Lakeview Parkway Vernon Hills, IL 60061 É.-U Distribué parPrecaución Información de seguridadAdvertencia Información de seguridadLa unidad de bolsillo puede ser llevada adonde usted vaya Características del productoSe puede inhalar utilizando distintos ángulos Cuidados sencillos y fácil usoNombres y funciones de las piezas Esta unidad debe armarse antes de su uso Cómo armar la unidad principalConecte el adaptador para mascarilla a la unidad principal En el adaptador para la mascarillaCómo colocar las pilas Cómo utilizar la fuente de alimentaciónDuración y recambio de las pilas Cómo sacar el transformador de CA de la unidad principalLlene el depósito para el medicamento Cómo llenar el depósito para el medicamentoCómo seleccionar el modo De nebulizaciónCómo inhalar Asegúrese de lavar y guardar la unidad después de usarla Cuidado de la unidad después de su usoCómo transportar la unidad Cuando la unidad principal esté suciaCómo reemplazar la tapa reticulada Cómo desinfectarSe pueden desinfectar las siguientes piezas Retire la tapa reticulada delSolución de problemas Solución de problemasEspecificaciones técnicas Solución de problemas y garantíaGarantía Especificaciones técnicasDistribuido por