SECTION 10—BATTERIES/CHARGER
Connecting/Disconnecting Battery Cables
WARNING
DO NOT remove fuse or mounting hardware from POSITIVE (+) RED battery cable/mounting screw.
All battery terminal covers (two on the front battery and two on the rear battery) MUST be installed prior to use.
Connecting Battery Cables
NOTE: For wheelchairs manufactured BEFORE 7/14/03, refer to FIGURE 10.3 and FIGURE 10.4 on page 92.
NOTE: For wheelchairs manufactured AFTER 7/14/03, refer to FIGURE 10.3 and FIGURE 10.5 on page 93.
1.Install battery terminal cap(s) onto battery cable(s) as follows (FIGURE 10.3):
A.ORANGE or RED battery terminal cap onto RED battery cable.
B.GREY or BLACK battery terminal cap onto BLACK battery cable.
CAUTION
When connecting the battery cables to the battery(ies), the battery cable(s) MUST be connected to the battery terminal(s)/post(s) as shown in “A” of FIGURE 10.5, (depending on battery type), otherwise damage to the battery cable may result when installing battery terminal caps.
Battery Cable
Battery Terminal Cap
FIGURE 10.3 Connecting Battery Cables
2.Connect battery cable(s) to battery(ies) terminal(s)/post(s) (“A”DETAILDETAILDETAIL of FIGURE 10.4 or FIGURE 10.5).
A.NEGATIVE (-) BLACK battery cable to NEGATIVE (-) battery terminal/post.
B.POSITIVE (+) RED battery cable to POSITIVE (+) battery terminal/post.
3.Secure the battery cable(s)/ring terminal(s) to the battery terminal(s)/post(s), BLACK to NEGATIVE (-) and RED to POSITIVE (+), with the provided 1/4-20 x 7/8-inch hex flange screw and hex flange locknut. Securely tighten.
4.Verify all battery cable(s)/ring terminal(s) are correctly installed and securely tightened.
5.Slide terminal cap(s) down battery cable(s) and onto battery clamps (DETAIL “B” of FIGURE 10.4 or FIGURE 10.5).
Part No 1118377 | 91 | Pronto® M71™ |