GE A071-0CG manual Overview, Product Perspective

Page 11

Overview

The ANSI X3.28/SRIO DPA software is installed in GE Energy Services WESDAC equipment to provide an interface to master stations using the ANSI X3.28 communication protocol.

Product Perspective

The ANSI X3.28/SRIO DPA software is custom software that will be installed in the GE Energy Services RTU to provide a communication link to master stations using the ANSI X3.28 communication protocol. The ANSI X3.28/SRIO DPA does not follow typical GE Energy Services DPA conventions, and interfaces directly to the SPABUS DCA.

The SPABUS DCA provides the only interface between the ANSI X3.2/SRIO DPA and WIN, and must be present in the system in order to use the ANSI X3.28/SRIO DPA. The DPA does not have access to the system WESDAC data tables, but only to data owned by the SPABUS DCA. The ANSI X3.28/SRIO DPA configuration tables reference the SPABUS configuration item table rather than the WESDAC tables. Figure 1 represents a complete system overview of how the DPA interfaces with the SPABUS DCA in a typical GE Energy Services RTU.

Restricted

A071-0CG-2.02-2

Full

 

xi

Image 11
Contents Ansi X3.28/SRIO DPA Trademark Notices Table of Contents Ansi X3.28/SRIO DPA List of Figures System Overview Xii Read Access FlagsAnsi X3.28/SRIO DPA List of Tables Viii Who Should Use this Guide About this GuidePurpose of this Guide Additional Documentation Product Perspective OverviewXii Ansi X3.28/SRIO DPA Configuration Tables Configuring TablesConfiguration Sequence Character Times Configuring the Main Table A071MAINAnsi X3.28/SRIO DPA GE Energy Services Baud Rate One Character Time ms Configuring the Mapping Tables Mapping Table Configuration Parameters Log-In User B014USER Configuring Wesmaint for the Ansi X3.28/SRIO DPARead Access Flags Ansi Application process died Appendix AError MessagesError Messages Fatal Error MessagesCant get enough memory for Ansi Application. Suspending Cant allocate rx sinksCant create required exchanges. Suspending Cant create T071 exchangeCant spawn/activate L071 process Cant set communications timersCant set configured bit rate Cant spawn/activate E071 processInvalid checksum configured Bcc or Crc Invalid AI offset configuredInvalid Analog Format configured 32 BIN, 6 or 3 BCD Invalid AO offset configuredInvalid embedded response enable Yes or No Invalid DD offset configuredInvalid DI offset configured Invalid do offset configuredInvalid OBJ offset configured Invalid Evnt offset configuredInvalid EV offset configured Invalid modem enable Yes or NoInvalid Retransmit digital configured -1 to Invalid parity configured None, Even, OddInvalid PD offset configured Invalid Retransmit analog configured -1 toMapped AO point not Found. Check config Invalid SYS offset configuredInvalid TM offset configured Mapped AI point not Found. Check configMissing Configuration ... Deleting Mapped DI point not Found. Check configMapped do point not Found. Check config Mapped EV point not Found. Check configAnsi X3.28/SRIO DPA Ascii Glossary of TermsWIN List of Acronyms and Abbreviations