GE A071-0CG manual Xii

Page 12

 

ANSI X3.28/SRIO DPA

GE Energy Services

CONFIGURATION GUIDE

Master

Control

System

Master

Command

Master

Response

 

WIN

 

Command

Master

WIN

Response

DPA

WIN

 

Event

WIN

 

Operator

Command

 

 

Request

WIN

 

 

 

Response

WESMAINT

Display

 

II

Data

WIN

 

 

Event

 

 

WESMAINT

Display

WESDAC

Interface

Node

 

 

 

DCA

 

D20

 

Command

 

Command

 

DCA

 

 

 

D20

D20

D20

Event

Peripherals

Response

DCA

DCA

 

 

 

Response

Project: G:\APPL\A070\R100\DOC\EASYCASE\ Chart: D20 data flow (FS) Filename: d20_flow.dfd

Last modified on: Nov-03-1992

by User: andy

DCA

 

SPABUS

Command

DCA

 

Response

 

SPABUS

Event

SPABUS

DCA

Command

DCA

 

Response

 

 

SPABUS SPABUS

Reply Request

ANSI

Command

ANSI X3.28

ANSI

DPA

Response

 

SPA

System

Substation

Control

System

(SCS)

Figure 1 System Overview

xii

A071-0CG-2.02-2

Restricted

 

Full

Image 12
Contents Ansi X3.28/SRIO DPA Trademark Notices Table of Contents Ansi X3.28/SRIO DPA System Overview Xii Read Access Flags List of FiguresAnsi X3.28/SRIO DPA List of Tables Viii About this Guide Purpose of this GuideWho Should Use this Guide Additional Documentation Overview Product PerspectiveXii Configuring Tables Ansi X3.28/SRIO DPA Configuration TablesConfiguration Sequence Configuring the Main Table A071MAIN Character TimesAnsi X3.28/SRIO DPA GE Energy Services Baud Rate One Character Time ms Configuring the Mapping Tables Mapping Table Configuration Parameters Configuring Wesmaint for the Ansi X3.28/SRIO DPA Log-In User B014USERRead Access Flags Appendix AError Messages Error MessagesFatal Error Messages Ansi Application process diedCant allocate rx sinks Cant create required exchanges. SuspendingCant create T071 exchange Cant get enough memory for Ansi Application. SuspendingCant set communications timers Cant set configured bit rateCant spawn/activate E071 process Cant spawn/activate L071 processInvalid AI offset configured Invalid Analog Format configured 32 BIN, 6 or 3 BCDInvalid AO offset configured Invalid checksum configured Bcc or CrcInvalid DD offset configured Invalid DI offset configuredInvalid do offset configured Invalid embedded response enable Yes or NoInvalid Evnt offset configured Invalid EV offset configuredInvalid modem enable Yes or No Invalid OBJ offset configuredInvalid parity configured None, Even, Odd Invalid PD offset configuredInvalid Retransmit analog configured -1 to Invalid Retransmit digital configured -1 toInvalid SYS offset configured Invalid TM offset configuredMapped AI point not Found. Check config Mapped AO point not Found. Check configMapped DI point not Found. Check config Mapped do point not Found. Check configMapped EV point not Found. Check config Missing Configuration ... DeletingAnsi X3.28/SRIO DPA Glossary of Terms AsciiWIN List of Acronyms and Abbreviations