GE A071-0CG manual Cant allocate rx sinks, Cant create required exchanges. Suspending

Page 24

 

ANSI X3.28/SRIO DPA

GE Energy Services

CONFIGURATION GUIDE

Can't allocate rx sinks

Cause:

Not enough RAM available for the receive buffer queue to be created.

Remedy:

Reduce the amount of memory used by this or other applications in the system.

Upgrade to a larger memory model.

Can't create required exchanges. Suspending

Cause:

The system cannot create the external interface inter-process message exchange.

Remedy:

Contact the Customer Service Department to report this error.

Can't create T071 exchange

Cause:

The system cannot create the external interface inter-process message exchange.

Remedy:

Contact the Customer Service Department to report this error.

Can't get enough memory for ANSI Application. Suspending

Cause:

The system cannot retrieve enough ram for operation of the ANSI DPA.

Remedy:

Reduce the amount of memory used by this or other applications in the system.

Upgrade to a larger memory model.

Can't allocate memory for event queue. Suspending !

Cause:

The system cannot retrieve enough ram for operation of the ANSI DPA.

Remedy:

Reduce the amount of memory used by this or other applications in the system.

Upgrade to a larger memory model.

Can't open communications port

Cause:

The system has found that this port is invalid, or already in use by another process.

Remedy:

Ensure the Port configured in A071MAIN contains a valid port name.

Ensure the Port configured in A071MAIN is not in use by another application.

A071-0CG-2.02-2Restricted

12

Full

 

Image 24
Contents Ansi X3.28/SRIO DPA Trademark Notices Table of Contents Ansi X3.28/SRIO DPA System Overview Xii Read Access Flags List of FiguresAnsi X3.28/SRIO DPA List of Tables Viii About this Guide Purpose of this GuideWho Should Use this Guide Additional Documentation Overview Product PerspectiveXii Configuring Tables Ansi X3.28/SRIO DPA Configuration TablesConfiguration Sequence Configuring the Main Table A071MAIN Character TimesAnsi X3.28/SRIO DPA GE Energy Services Baud Rate One Character Time ms Configuring the Mapping Tables Mapping Table Configuration Parameters Configuring Wesmaint for the Ansi X3.28/SRIO DPA Log-In User B014USERRead Access Flags Appendix AError Messages Error MessagesFatal Error Messages Ansi Application process diedCant allocate rx sinks Cant create required exchanges. SuspendingCant create T071 exchange Cant get enough memory for Ansi Application. SuspendingCant set communications timers Cant set configured bit rateCant spawn/activate E071 process Cant spawn/activate L071 processInvalid AI offset configured Invalid Analog Format configured 32 BIN, 6 or 3 BCDInvalid AO offset configured Invalid checksum configured Bcc or CrcInvalid DD offset configured Invalid DI offset configuredInvalid do offset configured Invalid embedded response enable Yes or NoInvalid Evnt offset configured Invalid EV offset configuredInvalid modem enable Yes or No Invalid OBJ offset configuredInvalid parity configured None, Even, Odd Invalid PD offset configuredInvalid Retransmit analog configured -1 to Invalid Retransmit digital configured -1 toInvalid SYS offset configured Invalid TM offset configuredMapped AI point not Found. Check config Mapped AO point not Found. Check configMapped DI point not Found. Check config Mapped do point not Found. Check configMapped EV point not Found. Check config Missing Configuration ... DeletingAnsi X3.28/SRIO DPA Glossary of Terms AsciiWIN List of Acronyms and Abbreviations