upper-right corner of the page . Then select Factory Restore, and click the Restore button.

Issue 4: Faulty Connection to Phone Lines

Problem: “There’s no dial tone.”

Cause: If you’ve eliminated the possibility that your phone service is down, the phone line might have lost connection to the base unit. The LEDs on the base unit should remain constantly lit when the associated phone line is properly configured. When the connection is faulty, the corresponding LED may flutter or sporadically flash on and off. For additional information regarding phone line-related malfunctions, see “Issue 7: Dropped Calls.”

Solution: Reconfigure the phone line using the configuration wizards in the Response Point Administrator.

Problem: “The Automated Receptionist is not answering calls, and callers hear incessant ringing.”

Cause: A single RJ11 line might be connected to the base unit, but you ordered two lines from your phone service provider. Standard RJ11 lines are designed to handle up to two phone lines on a single plug; however, the phone line adapter treats a single plug as a single line .

Solution: Install a splitter to separate the shared pins on the RJ11 plug.

Issue 5: Faulty Connection to Simple Mail Transfer

Protocol (SMTP) Server

Problem: “The voicemail-to-e-mail feature isn’t working properly. Users who have enabled this setting haven’t received any voice messages as e-mail attachments yet.”

Cause: The SMTP server settings are probably incorrect, if you’ve taken the following actions:

In the Response Point Administrator, selected the Allow sending voicemail in e-mail check box in the Configure E-mail Server dialog box—a required step before the individual setting that users configure can work.

Confirmed that all of the required fields in the Configure E-mail Server dialog box have the correct information.

In the Response Point Assistant, verified that users have selected the Enable voicemail check box on the Voicemail tab.

Solution 1: Visit the Web site of your Internet service provider, and locate the correct SMTP server settings. Taking this route, however, might force you to wade through unnecessary information before finding what you need. Try this shortcut instead: When you type “POP3 settings, <name of ISP>” in the search box of a Web browser, a list of search results containing the correct information will be available. Note the outgoing-SMTP-server address and the port number; then in the Response Point Administrator, enter this information in the corresponding fields before checking the connection by sending a test e-mail.

Solution 2: If you’ve deployed Response Point with Windows® Small Business Server, try adjusting the following

e-mail server settings in the Configure E-mail Server dialog box in the following order: 1) Click the Connect to the server anonymously option instead of specifying a user . 2) Under User Information, type “PhoneSystem@<insert your business e-mail alias>.com.” 3) Clear the This server requires SSL encryption check box.

Issue 6: Logon Attempts Failed

Problem: “After verifying that logon information is correct, users still can’t log in to Response Point Assistant.”

Cause: It might be that the computers running the Response Point Assistant are set up to use Internet Protocol security (IPsec), which is an unsupported environment for this application.

Solution: Make sure that the computers running the Response Point Assistant are not configured for IPsec.

Issue 7: Dropped Calls

Problem: “External callers are experiencing dropped calls.”

19 Technical Services: 800-283-5936

Image 23
Contents Administrator’s Guide Technical Support Appendix C Compliance Page Product Overview Product OverviewImportant safety information Microsoft Response Point Software Download UnpackSystem Requirements Connecting Additional MAX IP Response Point Phones InstallationConnecting your conference phone Manually provisioning your MAX IP Response Point phone Configuration of the MAX IP Response Point PhoneManually assigning an IP address Device Information screen Web Portal ScreensConfiguration User Preferences screen View Log Device Log File screen Configuration Trace/Logging Settings screenView Log Device Log File screen Tools Diagnostics VoIP Statistics screenTo Change Subnet Mask To Change Dynamic Host Configuration Protocol DhcpUser Options To Change Host IP AddressTo Restore Factory Defaults To Program a Default Gateway IP AddressMAX IP Response Point software Response Point ConfigurationInstalling Response Point Administrator To install AdministratorAdding a New Phone Response Point AdministratorConfiguring a Phone Using Response Point Administrator To add a new phone in Response Point AdministratorClick Add Phone Technical Services Troubleshooting Common Issues TroubleshootingTroubleshooting MAX IP Response Point TroubleshootingSix Questions to Ask Before Troubleshooting the System Response Point TroubleshootingIssue 3 Faulty Connection to Phone Issue 1 Undetected DevicesIssue 2 Unrecognized IP Addresses Issue 7 Dropped Calls Issue 4 Faulty Connection to Phone LinesIssue 5 Faulty Connection to Simple Mail Transfer Issue 6 Logon Attempts FailedIssue 10 Unlit Message Waiting Indicator MWI Issue 8 Low Call VolumeIssue 9 Speech Misrecognition Product registration Customer Service and SupportPage Dimensions W x D x H Appendix a SpecificationsAssessment Task Results Assessment checklistAppendix B Tools and Resources Technical Services 800-283-5936 Beta Planning Task Results Deployment checklistTechnical Services 800-283-5936 Beta Appendix C Compliance Safety 73/23/EEC Low Voltage Directive LVDCFO