Vertex Standard FTM-10R Storing Smart Search Memories, Scan Feature, Smart Searchtm Operation

Page 32

SMART MENU FEATURES

SCAN FEATURE

1. Press the top panel / key to select “SCAN”.

2. Press the key to initiate upward scanning.

When the scanner encounters a signal strong enough to open the squelch, the scanner will halt for five seconds, and then resume scanning.

3.To stop the scanner, press the or PTT key.

When the key function is set to “SCAN” via the top panel / key, the key may be used as the scan start/stop command key.

If you want to change the direction of the scan while it is underway, rotate the DIAL knob one click in the opposite direction (in this case, one click counter-clockwise). You will see the scanner reverse direction and scan down in frequency.

The decimal point of the frequency display while the Scan is activated. You may select the Scan Resume mode via the Menu Item “F26 RESUME”.

When you start the scanner in the memory mode, only the memorized memory channels will be scanned

SMART SEARCHTM OPERATION

The Smart Search feature allows you to load frequencies automatically according to where activity is encountered by your radio. When Smart Search is engaged, the transceiver will search above and below your current frequency, storing active frequencies as it goes (with- out stopping on them even momentarily). These frequencies are stored into a special Smart Search memory bank, consisting of 31 memories (15 above the current frequency, 15 be- low the current frequency, plus the current frequency itself). All channels where activity is present will be loaded into the Smart Search memories. The search will stop after one sweep in each direction, whether or not all 31 memories are filled.

Storing Smart Search Memories

1.

Set the radio to the VFO mode. Be sure that you have the Squelch adjusted properly (so

 

that band noise is quieted).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Press the top panel

/

key to select “SSCH”.

 

 

 

 

 

 

 

 

 

 

 

 

3.

Press the

 

key to initiate upward scanning.

 

 

 

 

 

 

4.

As active channels are detected, they will automatically be

 

 

 

 

 

 

 

 

 

 

 

 

stored into the Smart Search memory bank without causing the sweep to halt.

If you want to change direction of the Smart Search while it is underway, rotate the DIAL knob one click in the opposite direction (in this case, one click counter-clock- wise). You will see the scanner reverse direction and Smart Search down in frequency.

5.The Smart Search scan will eventually terminate, and the LCD will revert to Smart Search Memory Channel “<C>”.

30

FTM-10R OPERATING MANUAL

Image 32
Contents FTM-10R Contents Features New Concept in Ultra compact Mobile transceiversReliable and advanced performance Features Front Panel & TOP Panel KeysLED Rear Panel & LCD DC 13.8 V Cable Pigtail w/FuseRear Panel EXT SPK jackAccessories & Options Supplied AccessoriesOptional Accessories FEP-4Preliminary Inspection InstallationInstallation Tips Safety Information Mobile Installation Mobile Power Connections Mobile SpeakersAC Power Supplies Base Station InstallationAntenna Considerations Assumes 50-Ohm Input/Output TerminationsSeparate Installation Installation Front Panel Installation Installation Bracket Rubber NON-SEPARATE Installation Basic Operation ReceiveTransmission Smart Menu Features Display FunctionAF Dual Function Artstm Dimmer Function Dimmer 1 ÅÆ Dimmer 2 ÅÆ Dimmer 3 ÅÆMonitor Feature Intercom FunctionPublic Address Feature Reverse FeatureSmart Searchtm Operation Scan FeatureStoring Smart Search Memories Squelch Level Adjust TX Power Select Intercom Volume ControlMemory Operation Memory StorageAll Memory Channel Recall Group Memory Mode Memory RecallMemory Channel Customization Diaplay FunctionTo eliminate the memory channel from the Group Memory bank Memory Group BankMemory Channel Number Change Memory Channel SortLabeling Memory SKIP/PREFERENTIAL Scan Setting Scan TypeSquelch Level Ctcss FrequencyDCS Code Storing Independent Transmit Frequency ODD Split Using the Standard Repeater ShiftUsing the Odd Split Memory Transmitter Power Level Deleting MemoryActivating the Club Channel Monitor Club Channel OperationRecalling the Club Channel Club Channel Operation Message Feature Programming a MessageProgramming a Member List Preparations Source Transceiver Preparations Destination TransceiverCloning Cloning the MessageSending a Messages To send a messageSET Your Personal ID Receiving a Message CloningCopy/clone procedure is completed Changing the Club Channel Frequency CLOCK/TIMER Operation SET UP the ClockDisplays the Current Time Activate the ClockDisplay the Clock Using the Stop Watch Timer Using the Interval TimerAutomatic Audio Volume Controller Convenience FeaturesMute Feature AF-VFO Feature VOX OperationListening the AM/FM Broadcast Station TIME-OUT Timer TOTVOX Sensitivity Listening to External Audio Input FTM-10RBluetooth Operation PairingTo activate Bluetooth About the Bluetooth Battery IndicatorAF Dual Function AF Dual Function Ctcss Operation DCS Operation Storing the Ctcss Tone Pairs for Epcs Operation Epcsenhanced Paging & Code Squelch OperationActivating the Epcs Internet Connection Feature Wirestm SRG Sister Radio Group ModeFRG FRIENDS’ Radio Group Mode Programming the FRG codeTo accessing an FRG Node Dtmf Autodialer To load the DTMFAutodialer memoriesTo transmit the memorized telephone number Repeater Operation Standard Repeater ShiftBand Expansion Repeater OPERATION/BAND ExpansionAutomatic Repeater Shift Weather Broadcast Channel Operation Severe Weather AlertChannel Step Selection Miscellaneous SettingChanging the Operating Mode Smart KEY Select PTT KEY FunctionKEY Beeper Automatic Repeater Shift Repeater Shift DirectionRepeater Shift Offset Programming the KEY Assignments SCAN-RESUME Mode Scanning BandScan Direction Scan Start DirectionCTCSS/DCS/EPCS Bell Operation Split Tone OperationClock Format Battery Voltage DisplayTemperature Display Interval Beep Alarm SETTime System Automatic POWER-OFF APO Audio Pitch ControlVolume Setting Alert Feature Speaker SelectionMIC Gain Setting STEREO/MONAURAL SelectionMenu SET Mode Default Bold ItaricMenu Item Function Available Values Default Bold Itaric ENU ODECTCSS/DCS/DTMF Setting ODE ENUAmateur Bands SQL Set Mode Item F2 AF Dual Set Mode Item F1 AF AutoDefault OFF Set Mode Item F3 AF Pitch Set Mode Item F4 AF PrestSet Mode Item F5 AF-VFO Set Mode Item F6 BeepSet Mode Item F8 BLU VOX Default PTTSet Mode Item F9 Clock Available Values OFF/AUTO/HOLD Default OFFSet Mode Item F15 Fkey SEL Default PA Set Mode Item F16 ID ListSet Mode Item F17 ID REG Set Mode Item F18 MessageSet Mode Item F24 RPT ARS Set Mode Item F26 RPT SFTSet Mode Item F27 RX EXP Set Mode Item F28 RX F CCLSet Mode Item F33 SCN Strt Set Mode Item F32 SCN ModeDefault Busy Set Mode Item F37 SQL EXP Set Mode Item F35 SQL BellDefault OFF Set Mode Item F36 SQL DCS Set Mode Item F39 SQL Tsqf Set Mode Item F40 SQL TypeSet Mode Item F41 Step Set Mode Item F42 StereoSet Mode Item F45 VOL.ITCOM Set Mode Item F46 VOX MICSet Mode Item F47 VOX Sens Default Set Mode Item F48 WiresReset Procedure Troubleshooting Specifications Circuit Type SensitivitySquelch Sensitivity SelectivityDeclaration by Manufacturer 0704z-0E