MISCELLANEOUS SETTING

CHANNEL STEP SELECTION

Tuning steps are factory preset to default increments which are appropriate for the country to which this radio is exported. You may have a reason to use a different step size, however, and here is the procedure for changing the channel steps:

1.Press and hold the [VOL/SEL] key for one second to activate the Menu mode.

2.Rotate the DIAL knob to select Menu Item “F41 STEP”.

3.Press the key to enable selection of this Menu Item.

4.Rotate the DIAL knob to select the desired step size:

5.00, 6.25. 8.33, 10.00, 12.50, 15.00, 20.00, 25.00, 50.00, 100.00, 200.00 kHz or AUTO.

5.Press the [VOL/SEL] key to save the new setting and exit to normal operation. Note: 1) AM BC band only selects 9 kHz or 10 kHz.

Note: 2) FM BC band only selects 50 kHz, 100 kHz, or 200 kHz.

Note: 3) Steps of 5 kHz, 6.25 kHz, 8.33kHz, and 9 kHz are not available above 470 MHz.

CHANGING THE OPERATING MODE

The FTM-10Rprovides for automatic mode changing when the radio is tuned to different operating frequencies. However, should an unusual operating situation arise in which you need to change between the available operating modes (FM, FM-Narrow, FM-Wide, and AM), here is the procedure for doing so:

1.Press and hold the [VOL/SEL] key for one second to activate the Menu mode.

2.Rotate the DIAL knob to select Menu Item “F29 RX M MOD.”

3.Press the key to enable selection of the operating mode. The current operating mode appears on the LCD.

4.Rotate the DIAL knob to select the desired operating mode.

AUTO: Automatic mode setting per default values for the selected frequency range.

WIDE FM: Frequency Modulation for receiving an FM Broadcast Station.

FM: Frequency Modulation for receiving an Amateur Radio Station and most VHF/UHF Communication.

NARR FM: Frequency Modulation for receiving some Amateur Radio Stations and VHF/ UHF Communication.

AM: Amplitude Modulation for receiving a AM Radio Station and Air Band Com-

munication.

Press the [VOL/SEL] key to save the new setting and resume normal operation.

76

FTM-10R OPERATING MANUAL

Image 78
Contents FTM-10R Contents Features New Concept in Ultra compact Mobile transceiversReliable and advanced performance Features Front Panel & TOP Panel KeysLED Rear Panel & LCD DC 13.8 V Cable Pigtail w/FuseRear Panel EXT SPK jackAccessories & Options Supplied AccessoriesOptional Accessories FEP-4Installation Installation TipsPreliminary Inspection Safety Information Mobile Installation Mobile Power Connections Mobile SpeakersAC Power Supplies Base Station InstallationAntenna Considerations Assumes 50-Ohm Input/Output TerminationsSeparate Installation Installation Front Panel Installation Installation Bracket Rubber NON-SEPARATE Installation Basic Operation ReceiveTransmission Smart Menu Features Display FunctionAF Dual Function Artstm Dimmer Function Dimmer 1 ÅÆ Dimmer 2 ÅÆ Dimmer 3 ÅÆMonitor Feature Intercom FunctionPublic Address Feature Reverse FeatureScan Feature Storing Smart Search MemoriesSmart Searchtm Operation Squelch Level Adjust TX Power Select Intercom Volume ControlMemory Operation Memory StorageAll Memory Channel Recall Group Memory Mode Memory RecallMemory Channel Customization Diaplay FunctionTo eliminate the memory channel from the Group Memory bank Memory Group BankMemory Channel Number Change Memory Channel SortLabeling Memory SKIP/PREFERENTIAL Scan Setting Scan TypeSquelch Level Ctcss FrequencyDCS Code Using the Standard Repeater Shift Using the Odd Split MemoryStoring Independent Transmit Frequency ODD Split Transmitter Power Level Deleting MemoryClub Channel Operation Recalling the Club ChannelActivating the Club Channel Monitor Club Channel Operation Message Feature Programming a MessageProgramming a Member List Cloning Preparations Source TransceiverPreparations Destination Transceiver Cloning the MessageTo send a message SET Your Personal IDSending a Messages Receiving a Message CloningCopy/clone procedure is completed Changing the Club Channel Frequency CLOCK/TIMER Operation SET UP the ClockActivate the Clock Display the ClockDisplays the Current Time Using the Stop Watch Timer Using the Interval TimerConvenience Features Mute FeatureAutomatic Audio Volume Controller AF-VFO Feature VOX OperationTIME-OUT Timer TOT VOX SensitivityListening the AM/FM Broadcast Station Listening to External Audio Input FTM-10RBluetooth Operation PairingTo activate Bluetooth About the Bluetooth Battery IndicatorAF Dual Function AF Dual Function Ctcss Operation DCS Operation Storing the Ctcss Tone Pairs for Epcs Operation Epcsenhanced Paging & Code Squelch OperationActivating the Epcs Internet Connection Feature Wirestm SRG Sister Radio Group ModeFRG FRIENDS’ Radio Group Mode Programming the FRG codeTo accessing an FRG Node Dtmf Autodialer To load the DTMFAutodialer memoriesTo transmit the memorized telephone number Repeater Operation Standard Repeater ShiftRepeater OPERATION/BAND Expansion Automatic Repeater ShiftBand Expansion Weather Broadcast Channel Operation Severe Weather AlertMiscellaneous Setting Changing the Operating ModeChannel Step Selection PTT KEY Function KEY BeeperSmart KEY Select Repeater Shift Direction Repeater Shift OffsetAutomatic Repeater Shift Programming the KEY Assignments SCAN-RESUME Mode Scanning BandScan Direction Scan Start DirectionCTCSS/DCS/EPCS Bell Operation Split Tone OperationBattery Voltage Display Temperature DisplayClock Format Alarm SET Time SystemInterval Beep Automatic POWER-OFF APO Audio Pitch ControlVolume Setting Alert Feature Speaker SelectionMIC Gain Setting STEREO/MONAURAL SelectionMenu SET Mode Default Bold ItaricMenu Item Function Available Values Default Bold Itaric ENU ODECTCSS/DCS/DTMF Setting ODE ENUAmateur Bands SQL Set Mode Item F1 AF Auto Default OFFSet Mode Item F2 AF Dual Set Mode Item F5 AF-VFO Set Mode Item F3 AF PitchSet Mode Item F4 AF Prest Set Mode Item F6 BeepSet Mode Item F9 Clock Set Mode Item F8 BLU VOXDefault PTT Available Values OFF/AUTO/HOLD Default OFFSet Mode Item F17 ID REG Set Mode Item F15 Fkey SELDefault PA Set Mode Item F16 ID List Set Mode Item F18 MessageSet Mode Item F27 RX EXP Set Mode Item F24 RPT ARSSet Mode Item F26 RPT SFT Set Mode Item F28 RX F CCLSet Mode Item F32 SCN Mode Default BusySet Mode Item F33 SCN Strt Set Mode Item F35 SQL Bell Default OFF Set Mode Item F36 SQL DCSSet Mode Item F37 SQL EXP Set Mode Item F41 Step Set Mode Item F39 SQL TsqfSet Mode Item F40 SQL Type Set Mode Item F42 StereoSet Mode Item F47 VOX Sens Set Mode Item F45 VOL.ITCOMSet Mode Item F46 VOX MIC Default Set Mode Item F48 WiresReset Procedure Troubleshooting Specifications Squelch Sensitivity Circuit TypeSensitivity SelectivityDeclaration by Manufacturer 0704z-0E