OPERATION | ||
|
|
|
WIRE FEED (CONSTANT VOLTAGE) WELD- ING
(Stick and Wire models only)
Connect a wire feeder to the Commander 400 and set the welder controls according to the instructions in “Controls and Settings” in this section of the manual.
The Stick and Wire model of the Commander 400 with its CV tap, permits it to be used with a broad range of flux cored wire (Innershield and Outershield) electrodes and solid wires for MIG (GMAW).
For any electrodes, the procedures should be kept within the rating of this machine. For additional electrode infor- mation, see Lincoln publications
STICK AND WIRE MODEL CONNECTION TO LN-7 or LN-8
a.Shut the welder off.
b.Connect the
c.Set the “VOLTMETER” switch to either “+” or
d.Set the “RANGE” switch to the “WIRE WELDING CV” position.
e.Set the “OUTPUT CONTROL” switch to the “OUT- PUT REMOTELLY CONTROLLED” position.
f.Set the “IDLE” switch to the “HIGH” position.
STICK AND WIRE MODEL CONNECTION TO LN-25
The
a.Shut the welder off.
b.For electrode Positive, connect the electrode cable from the
c.Attach the single lead from the front of the
d.Set the range switch to “WIRE WELDING CV”
e.Set the “OUTPUT CONTROL” switch to “WELDING TERMINALS ALWAYS ON”
f.Set the “VOLTS\AMPS” switch to “VOLTS”
g.Set the “IDLE” switch to the “AUTO” position. When not welding , the Commander 400 S&W engine will be at the low idle speed. CAUTION: ( if you are using an
CAUTION
When the gun trigger is closed, the electrode is energised and the wire will begin to feed.
STICK AND WIRE MODEL CONNECTION TO LN-23P
a.Shut the welder off.
b.Connect the
d.Set the “RANGE” switch to “WIRE WELDING CV”
e.Set the “OUTPUT CONTROL” switch to “WELDING TERMINALS ALWAYS ON” Set the “VOLTS/AMPS” switch to “VOLTS”
g. Set the “LOCAL REMOTE” switch to the desired setting depending upon where the power sources output is being controlled from.
h.Set the “IDLE” switch to the “AUTO” position. When not welding , the Commander 400 Stick and Wire model engine will be at the low idle speed. If you are using an
STICK AND WIRE MODEL CONNECTION TO NA-3
For connection diagrams and instructions for connecting an
COMMANDER 400