Makita MAC1200 Hazard Risk to Breathing What can Happen, Ventilation, Risk from Flying Objects

Page 4

IMPORTANT SAFETY INSTRUCTIONS

HAZARD

RISK TO BREATHING

WHAT CAN HAPPEN

The COMPRESSED AIR from your compressor IS NOT SAFE FOR BREATHING! The air stream may contain

carbon monoxide or other toxic vapors, or particles from the tank or other

components.

SPRAYED MATERIALS such as paint, paint solvents, paint remover, insecticides, weed killers, etc., CONTAIN HARMFUL VAPORS and poisons.

HOW TO PREVENT IT

NEVER INHALE AIR FROM THE COMPRESSOR, either directly or from a

breathing device connected to the

compressor. WORK IN AN AREA equipped WITH GOOD CROSS-

VENTILATION.

Read and FOLLOW THE SAFETY INSTRUCTIONS provided on the label or safety data sheet FOR THE MATERIAL YOU ARE SPRAYING. USE A NIOSH/MSHA APPROVED RESPIRATOR designed FOR use with your specific APPLICATION.

RISK FROM FLYING

OBJECTS

. .. , :.:....,

.

":::.?

......:: ,.

RISK FROM MOVING

PARTS

l

RISK OF BURN

. .

. ,

The COMPRESSED AIR STREAM CAN cause soft tissue damage, and can PROPEL dirt, chips, loose PARTICLES and small objects at high speed, resulting in property damage or personal injury.

The COMPRESSOR CYCLES

AUTOMATICALLY WHEN the

PRESSURE SWITCH IS IN THE ON/ AUTO POSITION! If you attempt repair or maintenance while the compressor is operating, or with the switch in the ON/ AUTO position, you can expose yourself to moving parts. These MOVING PART: CAN CAUSE SERIOUS INJURY or damage if they come into contact with you or your clothing.

Contact with HOT PARTS such as the compressor head or outlet tubes

COULD RESULT IN A SERIOUS SKIN BURN.

t

ALWAYS WEAR ANSI 287.1 APPROVED SAFETY GLASSES with side shields when using the compressor.

NEVER POINT any nozzle or SPRAYER toward any part of the body or AT OTHER PEOPLE or animals.

Always TURN the COMPRESSOR QFJ AND BLEED PRESSURE from the air line BEFORE attempting maintenance, ATTACHING TOOLS or acceGories.

2

Always UNPLUG the COMPRESSOR AND RELEASE AIR PRESSURE from the tank and any attachments BEFORE ATTEMPTING any MAINTENANCE OR R EPAIR .

NEVER OPERATE the COMPRESSOR WITH GUARDS or covers which are

damaged or REMOVED.

5-

 

NEVER TOUCH HOT COMPONENTS during or immediately after operation of the compressor. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.

4

Image 4
Contents Specification Chart Model No MAC?Table of Contents Important Safety Instructions What can Happen HOW to Prevent ITHazard Risk to Breathing What can Happen VentilationRisk from Flying Objects Risk from MovingDuty Cycle General InformationON-RECEIPT Description of OperationInstallation and BREAK-IN Procedures Grounding InstructionThis unit needs no lubrication or oiling AdapterOperating Procedures Grounding Instruction contdWith or without yellow stripes Additional Regulators and ControlsMaintenance Units With External Brass Check ValveTroubleshooting Guide ProblemStorage CorrectionEquirement Spray area. See flammable vapor warningAIR Compressor Diagram Snug\34 23 50 to 60 in. IbsPart Number Description AC-0046AIR Compressor Pump Diagram 59uzAIR Compressor Pump Parts List NO. PartnumberService Notes MAC1200 Modelo No MAC1 Tabla DE EspecificacionesAmps Peligro Tabla DE ContenidosAadvertencia Riesgo QUE Puede SucederComo Evitarlo Conservar EstasinstruccionesInstrucciones Importantes RiesgoOUE Puedesuceder Como Ewtarlo VenenososGlosario Ciclo DE TrabajoInformacion General Inspeccion AL ReciberInstruccionesparaconectar Atierra Instalacion Y Procedimientos Para EL AsentamientoPuederesultar ENCHOQUEELECTRIC0 Procedimientos Para Operar Instalacion Y Procedimientos Para ELNota Instrucciones Para EL SERVlClO Programma DE Mantenimiento RUTlNARlOArrancadoy este funcionando Guia Para DIAGNOSTIC0 DE Problemas AlmacenajeProblemas GUiA Para DIAGNOSTIC0 DESolucion Diagrama DEL Compresor DE AlRE Numero Torque EndiagLista DE Partes DEL Compresor DE AlRE ParteAGO046 Numero EN42 a 48 Pulg. Lb Diagrama DE LA Bomba DEL Compresor DE AlREEN Diag Torque DESCRIPCI~N Magrama ParteSSG-8156 62 MO-9045 65 AGO140Notas Compresor DE Aire DE Lubricacion Permanente Tableau DES Specifications MAC120023/8pO 1 ~0 Remarque IMP QrtantTable DES Matieres Mesuresde SECURI~Listede verification quotidienne CompresseurdairMesures DE Securite Importantes CONSERVE2CES InstructionsRisque Declatement Risque DE Choc Elecxrique Risque DE FEU OU DexplosionMesuresde Securite Importantes con? Risque DE BroluresPrevention Risque DEDescription DU Mode Operationnel Facteur DutilisationRenseignements Generaux Verification SUR ReceptionInstallation ET Procedures DE Mise EN Route Directivesde Mise a LA TerreSi une rallongedevait Btreutilisee, assurez-vous Quelle est en bon etat Quelle nexcMe pas 50 piDirectives DE Mise a LA Terre Suite ProceduresoperationnellesProc6duresde mise en route Directives Dentretien Horaire Dentretien DE RoutineRemplacceparunesoupapedesoretede Entreposage ProblemecausePastrop Probleme Guide DE Depannage SuiteCause CORRECTlONCouple Diagramme DU Compresseur Dair23 50 a 60 livres-pouce LlSTE DES Pieces DU Compresseur Dair SS-&ZNDiagramme DE LA Pompe DU Compresseur Dair 5g-0DU Compresseur Dair Liste DES Pieces DE LA PompeMO-9045 AC-0032Page Guide DUTILlSATlON