3. FRONT PANEL CONTROLS & BASIC OPERATION | English |
3.2 Basic Operation
Refer to section 5 for a full description of each parameter.
3.2.1 General
(1)The inverter does not have a main power switch and is live when the mains supply is connected. It waits, with the output disabled, until the RUN button is pressed or for the presence of a digital ON signal at terminal 5 (rotate right) or terminal 6 (rotate left) - see parameters P051 - P053.
(2)If output frequency is selected to be displayed (P001 = 0), the corresponding setpoint is displayed approximately every 1.5 seconds while the inverter is stopped.
(3)The inverter is programmed at the factory for standard applications on Siemens
P084
P081
3 Mot |
| |||
IEC 56 | Nr. E D510 3053 | 12 022 | ||
IM B3 | ||||
IP54 | Rot. KL 16 | I.Cl.F | ||
| ||||
50 Hz 220/380 VΔ/Y | 60 Hz | 440 V Y |
| |
0,61/0,35 A |
| 0,34 A |
| |
0,12 kW |
| 0,14 kW |
| |
cosϕ 0,81 | cosϕ 0,81 |
|
| |
2745 /min |
| 3310 /min |
| |
VDE 0530 | S.F. - 1,15 |
|
|
P083 P082 P085
Figure 10: Typical Motor Rating Plate Example
Note: Ensure that the inverter is configured correctly to the motor, i.e. in the above example delta terminal connection is for 220 V.
3.2.2 Initial Testing
(1)Check that all cables have been connected correctly (section 2) and that all relevant product and plant/location safety precautions have been complied with.
(2)Apply mains power to the inverter.
(3)Ensure that it is safe to start the motor. Press the RUN button on the inverter. The display will change to 5.0 and the motor shaft will begin to turn. It will take one second for the inverter to ramp up to 5 Hz.
(4)Press the STOP button. The display will change to 0.0 and the motor slow to a complete stop within one second.