Siemens G85139 operating instructions Bestell-Nr SE9286-4AA86

Page 42

Herausgegeben vom

Bereich Antriebs-, Schalt- und Installationstechnik Geschäftsgebiet Antriebstechnik

Postfach 3269, D-91050 Erlangen

Siemens plc Sir William Siemens House Princess Road Manchester M20 8UR

Bestell-Nr. 6SE9286-4AA86

Änderungen vorbehalten

Specification subject to change without prior notice

G85139-H1750-U049-B

© Siemens plc 1997

Printed in EU

Image 42
Contents Micromaster Safety Instructions Overview Installation Wiring Guidelines to Minimise the Effects of EMIExample of an RFI Suppression Filter Installation Mechanical Installation Ideal InstallationHazard Frame Sizes All measurements in mm MMxxx MMxxx/2 ModelMMxxx/3 500 141 160 175 184 149 172 174 138 215 185 195 204 232Electrical Installation Power and Motor Connections Frame Size aSingle Phase Power ConnectionsPower and Motor Connections Frame Size B Power Connections Access Diagram Frame Size BPower and Motor Connections Frame Size C Power Connections Access Diagram Frame Size CControl Connections Front Panel RS485 D-typeControl Terminal Block Block Diagram Motor Overload ProtectionFront Panel Controls & Basic Operation Front Panel ControlsGeneral Initial TestingBasic Operation Refer to for a full description of each parameterBasic Operation 10 Step Guide Step /ActionButton Display Operating Modes 4.1 Digital Control Analogue ControlLocal and Remote Control Stopping the MotorIf the Motor Does Not Start Up Closed Loop Control Hardware SetupParameter Settings General DescriptionSystem Parameters Operating display P000Function Range Description / NotesP009 ∙ P004 ∙P005 ∙ P006 P007 FunctionP016 ∙ P011P012 ∙ P013 ∙ P014 ∙ P015 ∙ P017 ∙ P018 ∙P027 ∙ P028 ∙ P029 ∙ P031 ∙ P032 ∙ P022 ∙P023 ∙ P024 ∙ See P014P041 ∙ P042 ∙ P043 ∙ P044 ∙ P045 P046 ∙ P047 ∙ P048 ∙ P050P050 = P050 = 6 or P053 P051P052 P056P063 P061P062 P064P066 P073 ∙P074 ∙ P076 ∙ Inverter output terminals with power off P077P079 ∙ P081 P082 P083 P084 P085 P089 ∙ P091 ∙ P111 P112P113 P123 P121P122 P124P944 P947 P958 P963 P967 P968 P970 P971 ∙ Eeprom storage controlF151 F153 Fault CodesFault Code CauseSpecifications 16-8BB40 21-0BC40Please contact your local Options / AccessoriesAppropriate manner see .1 Siemens sales office forApplication Example Setup procedure for a simple applicationSupplementary Information USS Status CodesEMC Phenomenon Electro-Magnetic Compatibility EMCClass 1 General Industrial StandardClass 2 Filtered Industrial IEC 1000-2-4 ENV 50Standard Level EMC Class Environmental AspectsModel No Filter Class Filter Part NoP910 P918 P922 P923 P927 P928 P930 P931 P944 User’s Parameter SettingsP702 P880 P947 P958 P963 P967 P968 P970 P971Bestell-Nr SE9286-4AA86