Siemens G85139 Options / Accessories, Appropriate manner see .1, Please contact your local

Page 36

English

 

7. SPECIFICATIONS

Input frequency:

47 Hz to 63 Hz

 

 

 

 

 

 

Power factor:

λ ≥ 0.7

 

 

 

 

 

 

Output frequency range:

0 Hz to 400 Hz

 

 

 

 

 

 

Resolution:

0.01 Hz

 

 

Overload capability:

150% for 60 s, related to nominal current

 

 

 

Protection against:

Inverter overtemperature

 

 

Motor overtemperature

 

 

 

Overvoltage and undervoltage

 

Additional protection:

Against short-circuits and earth/ground faults pull-out protection.

 

Protection against running with no load (open-circuit)

 

 

 

Operating mode:

4 quadrants possible

 

Regulation and control:

Voltage/frequency curve

 

 

 

Analogue setpoint / PI Input:

0 - 10 V/2 - 10 V (recommended potentiometer 4.7 kΩ)

 

Analogue setpoint resolution:

10-bit

 

 

 

 

 

 

Setpoint stability:

Analogue < 1%

 

 

 

 

 

 

 

Digital < 0.02%

 

 

Motor temperature monitoring:

l2t control

 

 

 

 

 

 

Ramp times:

0 - 650 s

 

 

Control outputs:

1 relay 110 V AC / 0.4 A; 30 V DC / 1 A

 

WARNING: External inductive loads must be suppressed in an

 

appropriate manner (see section 2.1 (5)).

 

 

 

 

Interface:

RS485

 

 

Inverter efficiency:

97% (typically)

 

 

 

 

 

 

Operating temperature:

0oC to +50oC

 

 

Storage/transport temperature:

-40oC to +70oC

 

 

 

 

 

 

Ventilation:

Fan-cooled

 

 

Humidity:

90% non-condensing

 

 

 

 

Installation height above sea level:

< 1000 m

 

 

 

 

 

 

Note: If the Inverter is to be installed at an altitude >1000m,

 

 

derating will be required.(Refer to DA 64 Catalogue)

 

Degree of protection:

Frame size A:

IP20

 

 

(NEMA 1 using accessory kit - see options)

 

Frame sizes B & C: IP20 (NEMA 1)

 

 

(National Electrical Manufacturers’ Association)

 

 

 

Protective separation of circuits:

Double insulation or protective screening

 

Electro-magnetic compatibility (EMC):

See section 8.3

 

 

Options / Accessories

Additional RFI suppression filter

 

 

Clear Text Display (OPM2)

 

 

PROFIBUS module (CB15)

Please contact your local

SIMOVIS software for control via PC

Siemens sales office for

Output chokes and line chokes

further details

Output filters

 

 

IP20 (NEMA 1) Accessory Kit

 

 

 

 

 

G85139-H1750-U049-B

 

© Siemens plc 1997

26/09/97

36

 

 

 

Image 36
Contents Micromaster Safety Instructions Overview Installation Wiring Guidelines to Minimise the Effects of EMIExample of an RFI Suppression Filter Installation Mechanical Installation Ideal InstallationHazard MMxxx MMxxx/2 Model MMxxx/3 500Frame Sizes All measurements in mm 141 160 175 184 149 172 174 138 215 185 195 204 232Electrical Installation Power and Motor Connections Frame Size aSingle Phase Power ConnectionsPower and Motor Connections Frame Size B Power Connections Access Diagram Frame Size BPower and Motor Connections Frame Size C Power Connections Access Diagram Frame Size CControl Connections Front Panel RS485 D-typeControl Terminal Block Block Diagram Motor Overload ProtectionFront Panel Controls & Basic Operation Front Panel ControlsInitial Testing Basic OperationGeneral Refer to for a full description of each parameterBasic Operation 10 Step Guide Step /ActionButton Display Operating Modes 4.1 Digital Control Analogue ControlLocal and Remote Control Stopping the MotorIf the Motor Does Not Start Up Hardware Setup Parameter SettingsClosed Loop Control General DescriptionSystem Parameters P000 Function RangeOperating display Description / NotesP004 ∙ P005 ∙ P006 P007P009 ∙ FunctionP011 P012 ∙ P013 ∙ P014 ∙ P015 ∙P016 ∙ P017 ∙ P018 ∙P022 ∙ P023 ∙ P024 ∙P027 ∙ P028 ∙ P029 ∙ P031 ∙ P032 ∙ See P014P041 ∙ P042 ∙ P043 ∙ P044 ∙ P045 P046 ∙ P047 ∙ P048 ∙ P050P050 = P050 = 6 or P051 P052P053 P056P061 P062P063 P064P066 P073 ∙P074 ∙ P076 ∙ Inverter output terminals with power off P077P079 ∙ P081 P082 P083 P084 P085 P089 ∙ P091 ∙ P111 P112P113 P121 P122P123 P124P944 P947 P958 P963 P967 P968 P970 P971 ∙ Eeprom storage controlFault Codes Fault CodeF151 F153 CauseSpecifications 16-8BB40 21-0BC40Options / Accessories Appropriate manner see .1Please contact your local Siemens sales office forSetup procedure for a simple application Supplementary InformationApplication Example USS Status CodesElectro-Magnetic Compatibility EMC Class 1 General IndustrialEMC Phenomenon StandardClass 2 Filtered Industrial IEC 1000-2-4 ENV 50Standard Level Environmental Aspects Model NoEMC Class Filter Class Filter Part NoUser’s Parameter Settings P702 P880P910 P918 P922 P923 P927 P928 P930 P931 P944 P947 P958 P963 P967 P968 P970 P971Bestell-Nr SE9286-4AA86