Hitachi L300P Series service manual 2nd motor

Page 8

Function mode

 

Code

Function name

SJ300 Setting range

Initial data

Note

 

-FE/-FU/-F

 

 

 

 

 

 

b012

Electronic thermal level

0.2*constant current-1.20*constant current(A)

Rated

 

 

Current of

 

 

 

 

 

inverter

 

 

b212

Electronic thermal level

0.2*constant current-1.20*constant current(A)

Rated

 

 

Current of

 

 

(2nd motor)

 

 

 

 

Inverter

 

 

b312

Electronic thermal level

0.2*constant current-1.20*constant current(A)

Rated

 

 

(3rd motor)

current of

 

 

inverter

 

 

 

 

 

 

 

b013

1s t electronic thermal

00(reduced characteristic)/ 01(constant torque characteristic)/

01/01/00

 

 

characteristic selection

02(free setting)

 

thermal

 

 

 

b213

2nd electronic thermal

00(reduced characteristic)/ 01(constant torque characteristic)/

01/01/00

 

characteristic selection

02(free setting)

 

 

 

 

b313

3rd electronic thermal

00/(reduced characteristic)01(constant torque characteristic)/

01/01/00

 

Electronic

characteristic selection

02(free setting)

 

 

 

 

 

 

 

 

 

b015

Free electronic thermal

0.-400.(Hz)

0.

 

 

frequency 1

 

 

 

 

 

 

 

b016

Free electronic thermal

0.0-1000.(A)

0.0

 

 

current 1

 

 

 

 

 

 

 

b017

Free electronic thermal

0.-400.(Hz)

0.

 

 

frequency 2

 

 

 

 

 

 

 

b018

Free electronic thermal

0.0-1000. (A)

0.0

 

 

current 2

 

 

 

 

 

 

 

b019

Free electronic thermal

0.-400.(Hz)

0.

 

 

frequency 3

 

 

 

 

 

 

 

b020

Free electronic thermal

0.0-1000.(A)

0.0

 

 

current 3

 

 

 

 

 

 

 

b021

Overload restriction selection

00(invalid)/01(enabled on acceleration / constant speed)/

01

 

 

02(enabled on constant speed)/03(enabled on acceleration / constant

 

 

 

 

speed (speed increasing at regenerating mode))

 

 

 

b022

Overload restriction level

0.50* rated current-2.00* rated current(A) <-1.80*ratede current(A)>

Rated current

 

 

of Inverter

 

 

 

 

 

x 1.50

 

 

b023

Overload restriction limit

0.10-30.00(s)

1.00

 

 

constant

 

 

 

 

 

 

limit

b024

Overload restriction 2

00(invalid)/01(enabled on acceleration / constant speed)/

01

 

02(enabled on constant speed)/03(enabled on acceleration / constant

 

selection

 

Overload

 

speed (speed increasing at regenerating mode))

x1.50

 

 

 

 

 

 

 

 

 

 

b025

Overload restriction level 2

0.50*rated current-2.00*rated current(A) <-1.80*rated current(A)>

Rated current

 

 

of inverter

 

 

 

 

 

 

 

 

b026

Overload restriction constant

0.10-30.00(s)

1.00

 

 

2

 

 

 

 

 

 

 

 

 

00(impossible to change the data except this item when SFT terminal is

 

 

 

 

 

ON)/01(impossible to change the data except setting frequency item

 

 

 

b031

Software lock mode selection

when SFT terminal is ON)/02(impossible to change the data except this

01

 

 

item)/

 

 

 

 

 

 

 

 

 

03(impossible to change the data except setting frequency item)/

 

 

 

 

 

10(possible to change data on operating)

 

 

 

b100

Free V/f frequency 1

0.- Free V/f frequency2(Hz)

0.

 

 

b101

Free V/f voltage 1

0.-800.0(V)

0.0

 

 

b102

Free V/f frequency 2

0.- Free V/f frequency3(Hz)

0.

 

 

b103

Free V/f voltage 2

0.-800.0(V)

0.0

 

 

b104

Free V/f frequency 3

0.- Free V/f frequency4(Hz)

0.

 

setting

b105

Free V/f voltage 3

0.-800.0(V)

0.0

 

b107

Free V/f voltage 4

0.-800.0(V)

0.0

 

 

b106

Free V/f frequency 4

0.- Free V/f frequency5(Hz)

0.

 

V/f

 

 

 

 

 

 

b108

Free V/f frequency 5

0.- Free V/f frequency6(Hz)

0.

 

Free

b109

Free V/f voltage 5

0.-800.0(V)

0.0

 

 

b110

Free V/f frequency 6

0.- Free V/f frequency7(Hz)

0.

 

 

b111

Free V/f voltage 6

0.-800.0(V)

0.0

 

 

b112

Free V/f frequency 7

0.-400.(Hz)

0.

 

 

b113

Free V/f voltage 7

0.-800.0(V)

0.0

 

 

C001

Intelligent input 1 setting

01/(RV:Reverse is valid)/02(CF1:Multi-speed1)/ 03(CF2:Multi-speed2)/

18

 

 

04(CF3:Multi-speed3)/ 05(CF4:Multi-speed4)/ 06(JG:Jogging)/

 

setting

C002

Intelligent input 2 setting

16

 

07( DB:External DC braking)/ 08(SET:2nd control)/

 

 

 

 

09(2CH:two-stage adjustable speed)/ 11( FRS:Free-run)/ 12( EXT:External trip)/

 

 

terminal

 

 

13( USP:Unattended start protection)/ 14(CS:commercial change)/

 

 

 

 

15(SFT:software lock)/ 16(AT:Analog input voltage/current select)/

 

 

 

 

 

 

 

 

C003

Intelligent input 3 setting

17(SET3:3rdcontrol)/ 18(RS:Reset inverter)/ 20(STA:3wire run)/

06

 

input

 

 

21(STP:3wire keep)/ 22(F/R:3wire forward/reverse)/

 

 

 

 

23(PID:PID selection valid/invalid)/ 24(PIDC:PID integrating reset)/

 

 

 

C004

Intelligent input 4 setting

11

 

Intelligent

26( CAS:Control gain switch function)/ 27( UP:Remote control UP function)/

 

 

 

28( DWN:Remote control DOWN function)/29( UDC:Remote control data clear)/

 

 

 

 

 

31( OPE:Operating by operator select)/ 32(SF1:Multi-speed bit1)/

 

 

 

C005

Intelligent input 5 setting

09

 

 

33(SF2:Multi-speed bit2)/ 34(SF3:Multi-speed bit3)/ 35(SF4:Multi-speed bit4)/

 

 

 

 

36(SF5:Multi speed bit5)/ 37(SF6:Multi-speed bit6)/ 38(SF7:Multi-speed bit7)/

 

 

 

C006

Intelligent input 6 setting

03/13/03

 

 

39( OLR:Overload restriction change) / 40(TL:Torque limit select)/

 

 

 

 

41(TRQ1:Torque limit switch 1)/ 42(TRQ2:Torque limit switch 2)/

 

 

 

C007

Intelligent input 7 setting

02

 

 

43((PPI:P/PI switch)/ 44(BOK:Braking comformation)/ 45( ORT:Orientation)/

 

 

 

 

 

 

 

 

 

46(LAC:LAD cancel)/ 47(PCLR:Position error clear)/

 

 

 

C008

Intelligent input 8 setting

01

 

 

48(STAT:Permission of pulse train)/ no(NO:No assign)

 

 

 

 

 

 

 

 

 

 

 

 

(Note) < > indicate the setting range of 75 to 150kW

1- 5

Image 8
Contents Hitachi Inverter Revision History Table Inverter specification Investigation of the inverter Inverter specification 1 SJ300Function Mode Code 2nd motor Signal output mode Others Allowable motor selection 20-75.0kW 160kW User 2 L300P FE/-FU/-FR PID Terminal Meter C083 O2 adjustment 9999./1000-655310000-65530 U006 User6 selection Trouble Shooting Inverter trip contents, remedy, adviceIgbt Device- Net option board SJ-DN Option error Feed-back board SJ-FBDigital-input option board SJ-DG Check of the trip monitor contents Check of the warning monitor contents Return to an initialization setup Factory-shipment state Debug Mode Monitor modeFunction mode USAInitial cofiguration completion check procedure Setup of an inverterSetting procedure Model selection code C198 Code SJ300 L300P Control power supply Control signalMaintenance and Inspection Daily and annual maintenance Megger test How to check inverter & converter portion Parts replacement How to remove cooling fan for steel case How to fix DC bus capacitors for mold case Unit replacement English Internal block diagram SJ300-004-007LF Circuit Diagram SJ300-015 055LF Circuit Diagram SJ300-075-110LF , L300P-110-150LFR Circuit Diagram SJ300-150 220LF , L300P-185 300LFR Circuit Diagram SJ300-300LF, L300P-370LFR Circuit Diagram SJ300-370-450LF, L300P-450-550LFR Circuit Diagram SJ300-550LF,L300P-750LFR Circuit Diagram SJ300-007HF Circuit Diagram SJ300-015-055HF Circuit Diagram SJ300-075-110HF , L300P-110-150HFR Circuit Diagram SJ300-150 220HF , L300P-185 300HFR Circuit Diagram SJ300-300HF , L300P-370HFR Circuit Diagram SJ300-370- 550HF,L300P-450-750HFR Circuit Diagram DM Board SJ300-750-1320HF , L300P-900-1320HFR Circuit Diagram Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page SJ300/L300P Series Spare Parts List SJ3 CT PCB DM PCB NGMB25