Hitachi L300P Series service manual English

Page 38

No.

English

1

CB circuit / DC bus capacitor circuit

2

CB board / DC bus capacitor board

3

Instantaneous power failure detection

4

Phase failure detection

5

Opt coupler / Photo coupler

6

Reference voltage

7

Inrush current limiting (circuit)

8

Thyrister drive circuit (Suppressing circuit)

9

Power supply for Thyrister gate

10

Control signal for Thyrister

11

BRD drive circuit (incl. Short circuit protection)

12

Control signal for BRD

13

Short circuit detection

14

Power supply for lower arm IGBTs

15

Drive circuit for lower arm IGBTs (incl.Short circuit detection)

16

Drive circuit for upper arm IGBTs (incl.Short circuit detection)

17

Power supply for U phase

18

Current detection for U phase

19

Current detection for W phase

20

Control power supply

21

Temperature detection

22

Control power supply

23

Power supply for GA (Gate Array)

24

Power supply for I/F (interface)

25

UV (Under voltage) detection

26

Instantaneous power failure detection

27

Dividing circuit

28

OV (Over voltage) detection

29

Voltage detection for earch phase

30

f,sita detection

31

Main PCB

32

High speed opt coupler

33

Isolation amplifier

34

30 connections between main PCB and logic PCB

35

"H" while BRD ON

36

Approx. 3.3V peak at rated current

37

"L" while Inverter trips

38

"L" while phase failure

39

Communication signal,operates while standstill

40

PWM signal

41

Approx. 6.4V at OV level

42

"L" while stopped by Gate suppressing

43

Signal for frequency matching

44

Control power supply for digital portion

45

Control power supply for analog portion

46

Power supply for I/F (interface)

47

"H" while instantaneous power failure

48

OC(Over current)detection

49

Hardware latch

50

25 control terminals

51

31 control terminals

52

Logic PCB

Image 38
Contents Hitachi Inverter Revision History Table Inverter specification Investigation of the inverter Inverter specification 1 SJ300Function Mode Code 2nd motor Signal output mode Others Allowable motor selection 20-75.0kW 160kW User 2 L300P FE/-FU/-FR PID Terminal Meter C083 O2 adjustment 9999./1000-655310000-65530 U006 User6 selection Trouble Shooting Inverter trip contents, remedy, adviceIgbt Device- Net option board SJ-DN Option error Feed-back board SJ-FBDigital-input option board SJ-DG Check of the trip monitor contents Check of the warning monitor contents Return to an initialization setup Factory-shipment state Debug Mode Monitor modeFunction mode USAInitial cofiguration completion check procedure Setup of an inverterSetting procedure Model selection code C198 Code SJ300 L300P Control power supply Control signalMaintenance and Inspection Daily and annual maintenance Megger test How to check inverter & converter portion Parts replacement How to remove cooling fan for steel case How to fix DC bus capacitors for mold case Unit replacement English Internal block diagram SJ300-004-007LF Circuit Diagram SJ300-015 055LF Circuit Diagram SJ300-075-110LF , L300P-110-150LFR Circuit Diagram SJ300-150 220LF , L300P-185 300LFR Circuit Diagram SJ300-300LF, L300P-370LFR Circuit Diagram SJ300-370-450LF, L300P-450-550LFR Circuit Diagram SJ300-550LF,L300P-750LFR Circuit Diagram SJ300-007HF Circuit Diagram SJ300-015-055HF Circuit Diagram SJ300-075-110HF , L300P-110-150HFR Circuit Diagram SJ300-150 220HF , L300P-185 300HFR Circuit Diagram SJ300-300HF , L300P-370HFR Circuit Diagram SJ300-370- 550HF,L300P-450-750HFR Circuit Diagram DM Board SJ300-750-1320HF , L300P-900-1320HFR Circuit Diagram Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page SJ300/L300P Series Spare Parts List SJ3 CT PCB DM PCB NGMB25